26
Programming Guide
PGM Options
1
If a PGM delay is programmed (OFF option), the deactivation event can be used as a second activation event.
Table 12: Description of PGM options
Option Description
PGM 1 [261]
PGM 2 [262]
PGM 3 [263]
PGM 4 [264]
PGM 5 [265]
PGM 6 [266]
PGM 7 [267]
PGM 8 [268]
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
1
PGM base time (OFF = sec., ON = min.)
2
PGM state (OFF = N.O.; ON = N.C.)
3
PGM supervision
4
PGM activation mode
(OFF = steady; ON = pulse)
5
PGM pulse once every 30 seconds, if armed
6
PGM pulse on any alarm
7
PGM pulse on any alarm (OFF = partition 1;
ON = partition 2)
8
Flexible PGM deactivation option
(OFF
1
= PGM delay only, two activation
events; ON = PGM delay or deactivation
event, whichever comes first)
Option Description
PGM 9 [269]
PGM 10 [270]
PGM 11 [271]
PGM 12 [272]
PGM 13 [273]
PGM 14 [274]
PGM 15 [275]
PGM 16 [276]
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
1
PGM base time (OFF = sec., ON = min.)
2
PGM state (OFF = N.O.; ON = N.C.)
3
PGM supervision
4
PGM activation mode (OFF = steady;
ON = pulse)
5
PGM pulse once every 30 seconds, if armed
6
PGM pulse on any alarm
7
PGM pulse on any alarm (OFF = partition 1;
ON = partition 2)
8
Flexible PGM deactivation option
(OFF
1
= PGM delay only, two activation
events; ON = PGM delay or deactivation
event, whichever comes first)
= Default Setting
Содержание MG5050+
Страница 1: ...32 Zone Wireless Security System MG5050 Programming Guide ...
Страница 63: ......