Programming Guide
19
Description
of
Events
Table 11: List of events
Event Group
Event Group Description
Sub-group
Sub-group Description
00
Zone OK
01 to 32
Zone number
01
Zone open
99
Any zone number
02
Partition status
00 to 01
-
02
Silent alarm
03
Buzzer alarm
04
Steady alarm
05
Pulsed alarm
06
Strobe
07
Alarm stopped
08
Squawk ON (partition 1only)
09
Squawk OFF (partition 1 only)
10
Ground start (partition 1 only)
11
Disarm partition
12
Arm partition
13
Entry delay started
14
Exit delay started
15
Pre-alarm delay
16
Report confirmation
99
Any partition status event
03
Bell status (partition 1 only)
00
Bell OFF
01
Bell ON
02
Bell squawk arm
03
Bell squawk disarm
99
Any bell status event
06
Non-reportable event
00
Telephone line trouble
01
CLEAR
+
ENTER
, or
was pressed for 3 secs. (partition 1 only)
02
-
03
Arm in Stay mode
04
Arm in Sleep mode
05
Arm in Force mode
06
Full arm when armed in Stay mode
07
PC fail to communicate (partition 1 only)
08
Utility key 1 pressed (keys
1
and
2
; partition 1 only)
09
Utility key 2 pressed (keys
4
and
5
; partition 1 only)
10
Utility key 3 pressed (keys
7
and
8
; partition 1 only)
11
Utility key 4 pressed (keys
2
and
3
; partition 1 only)
12
Utility key 5 pressed (keys
5
and
6
; partition 1 only)
13
Utility key 6 pressed (keys
8
and
9
; partition 1 only)
14
Tamper generated alarm
15
Supervision loss generated alarm
16
-
17
-
18
-
19
-
20
Full arm when armed in Sleep mode
21
Firmware upgrade (partition 1 only; non-PGM event)
22
-
23
StayD mode activated
24
StayD mode deactivated