Programming Guide
49
Bell absent
1 321
Bell 1
YA
Bell fault
Clock lost
1 626
Time/date inaccurate
JT
Time changed
Fire loop trouble
1 373
Fire trouble
FT
Fire trouble
Communication fail
1 354
Communication fail
YC
Fail to communicate
RF jamming
1 344
RF receiver jam detection
XQ
RF jamming
GPRS module RF interference
1 552
Radio transmitter disabled
YS
Communication trouble
GPRS network failure
1 552
Radio transmitter disabled
YS
Communication trouble
GPRS supervision lost
1 552
Radio transmitter disabled
YS
Communication trouble
GPRS fail to communicate
1 354
Communication fails
YC
Fail to communicate
IP network failure
1 552
Radio transmitter disabled
YS
Communication trouble
IP supervision lost
1 552
Radio transmitter disabled
YS
Communication trouble
IP fail to communicate
1 354
Communication fails
YC
Fail to communicate
TLM trouble restore
3 351
Telco 1 fault restore
LR
Phone line restoral
AC failure restore
3 3A1
AC loss restore
AR
AC restoral
Battery failure restore
3 3A9
Battery test restore
YR
System battery restoral
Auxiliary supply trouble restore
3 3AA
System trouble restore
YQ
Power supply restored
Bell output current limit restore
3 321
Bell 1 restore
YH
Bell restored
Bell absent restore
3 321
Bell 1 restore
YH
Bell restored
Clock programmed
3 625
Time/date reset
JT
Time changed
Fire loop trouble restore
3 373
Fire trouble restore
FJ
Fire trouble restore
Fail to communicate with monitoring station restore
3 354
Fail to communicate restore
YK
Communication fails restore
RF jamming restore
3 344
RF receiver jam detection restore
XH
RF jamming restoral
GPRS module RF interference restore
3 552
Radio transmitter restore
YK
Communication restore
GPRS network restore
3 552
Radio transmitter restore
YK
Communication restore
GPRS supervision restore
3 552
Radio transmitter restore
YK
Communication restore
GPRS fail to communicate restore
3 354
Communication restore
YK
Fail to communicate restore
IP network restore
3 552
Radio transmitter restore
YK
Communication restore
IP supervision restore
3 552
Radio transmitter restore
YK
Communication restore
IP fail to communicate restore
3 354
Communication restore
YK
Fail to communicate restore
Combus fault
1 333
Expansion module failure
ET
Expansion trouble
Module tamper
1 341
Expansion module tamper
TA
Tamper alarm
Module AC fail
1 342
AC failure on module
AT
Module AC fail
Module battery fail
1 338
Battery failure on module
YT
Module battery fail
Bus fault restore
3 333
Expansion module failure restore
ER
Expansion restoral
Module tamper restore
3 341
Expansion module tamper restore
TR
Tamper restoral
Module AC fail restore
3 342
AC restored on module
AR
Module AC fail restore
Module battery fail restore
3 338
Battery failure on module
YR
Module battery fail restore
Cold start
1 3A8
System shutdown
RR
Power up
Test report engaged
1 6A2
Periodic test report
TX
Test report
PC software communication finished
1 412
Successful - download access
RS
Remote program success
Installer on site
1 627
Program mode entry
LB
Local program
Installer programming finished
1 628
Program mode exit
LS
Local program success
Maintenance in
1 627
Program mode entry
LB
Local program
Maintenance out
1 628
Program mode exit
LS
Local program success
Closing delinquency
1 654
System inactivity
CD
System inactivity
Manual trigger test in
1 6A1
Manual trigger test in
TS
Manual trigger test in
Manual trigger test out
3 6A1
Manual trigger test out
TS
Manual trigger test out
Exit error
1 374
Exit error
EE
Exit error
RF module low battery
1 384
RF transmitter low battery
XT
Transmitter battery trouble
RF module battery restore
3 384
RF transmitter battery restore
XR
Transmitter battery restoral
Table 41: List of automatic report codes (Continued)
System Event Default Contact ID Report Code
Default SIA Report Code
Содержание MG5050+
Страница 1: ...32 Zone Wireless Security System MG5050 Programming Guide ...
Страница 63: ......