Programming Guide
41
Communication Programming
Use the following section to program various communication features on your control panel. Table 32 lists features available for each control
panel.
Prioritization of signals and messages are based on a “first in, first out” scheme. Systems meet EN 50136 ATS2 or ATS3 requirements when configured as depicted.
NOTE:
For increased security, it is suggested that redundant communication methods be installed.
Dialer Options
Table 32: Communication features for panels
Communication Feature
Control Panel
GPRS reporting (PCS series)
SMS (PCS series)
IP reporting (IP Module)
E-mail/monitoring (IP Module)
Patented dialer
Table 33: Description of dialer options for landline communication (section [800])
Option
Description
OFF
ON
Option
Description
Sec
tion
[800]
1 & 2
Telephone line monitoring
See options 1
& 2, on right
See options 1
& 2, on right
3
Switch to pulse on fifth attempt
Disabled
Enabled
1
2
4
Alternate dial
Disabled
Enabled
OFF
OFF
Disabled (default)
5
Force dial (must be enabled to comply with TBR-21)
Disabled
Enabled
OFF
ON
Trouble only
6
DTMF dialing
Disabled
Enabled
ON
OFF
When disarmed: trouble only; when
armed: audible only
7
Pulse ratio
1:2
1:1.5
ON
ON
Silent alarms become audible alarm
8
Reporting*
Dialer
activated
No dialer
= Default
* This option also applies to landline.
Table 34: Description of general communication dialer options (section [801])
Option
Description
OFF
ON
Sec
tion
[801]
1
Report system disarming
Always
After alarm
2
Report zone restore
Bell cutoff
Zone closure
3 & 4
Auto-test report transmission
5
Contact ID override
Disabled
CID defaults/slow format
custom
6
Future Use
-
-
-
-
7
Future Use
-
-
-
-
8
Future Use
-
-
-
-
= Default
Table 35: Auto-test report transmission options (section [801])
Option
Description
3
4
1
OFF
OFF
Transmit the test report code when the days programmed in section
[840]
have elapsed, at the time programmed in section
[850]
(default).
2
OFF
ON
When disarmed: transmit test report code when the time programmed in section
[852]
has elapsed. When armed: transmit test
report code when the time programmed in section
[851]
has elapsed.
3
ON
OFF
The control panel will transmit the test report code every hour, on the minute value programmed in section
[850]
(the last two
digits); the first two digits of section
[850]
will be ignored. For example, if
10:25
was programmed into section
[850]
, the test
report code would be transmitted at the 25th minute of every hour, i.e., 11:25, 12:25, etc.
4
ON
ON
The test report code will be transmitted when the conditions in entries 2 or 3 above (option 3 = OFF and option 4 = ON; option 3
= ON and option 4 = OFF), are met.