60
Programming Guide
Appendix A
EN 50131 Programming
The following sections describe all the programming required for your panel to be EN 50131 compliant.
To set your panel to be EN 50131 compliant:
1.
Enter section [951] to unlock the software and set EN 50131 defaults.
2.
Press Enter.
NOTE:
All keypads in the system must have anti-tamper enabled in order to be EN 50131 compliant.
EN 50131 Standard System Defaults
The following sections are provide the system defaults that will be set for EN50131 compliancy. The following provides information on sections
[700]
through
[840].
Zone Tamper and Supervision Options
Table 52: Description of section [700]
Section
Option
Option Type
Description
OFF
ON
Sec
tion
[700]
1
Partitioning
Partitioning
Disabled
Enabled
2
General system options
Battery charging
350mA
700mA
3
Audible trouble warning (except AC failure)
Disabled
Enabled
4
Audible trouble warning on AC failure
Disabled
Enabled
5
RF jamming supervision
RF jamming supervision
Disabled
Enabled
6
General system options
Exit delay termination
Disabled
Enabled
7
Tamper supervision on the bus module
Disabled
Enabled
8
Panel Tamper
Panel Tamper Supervision
Disabled
Enabled
Table 53: Description of section [703]
Section
Option
Option Type
Description
OFF
ON
Se
c
ti
o
n
[703]
1
Keypad options 2
One-touch regular arming (also REM3)
Disabled
Enabled
2
One-touch stay arming (also REM3)
Disabled
Enabled
3
One-touch sleep arming (also REM3)
Disabled
Enabled
4
One-touch bypass programming
Disabled
Enabled
5
Arming/disarming options
Restrict arming on battery failure
Disabled
Enabled
6
Restrict arming on tamper failure (zone + bus
wireless PGM)
Disabled
Enabled
7
Restrict arming on supervision trouble;
wireless zones & PGM + bus module
Disabled
Enabled
8
Future Use
-
-
-
-
-
Table 54: Description of section [705]
Option
Description
OFF
ON
Se
c
ti
o
n
[705]
1
Future Use
-
-
-
-
2
Future Use
-
-
-
-
3
Tamper recognition (see following table)
Disabled
Enabled
4
Disabled
Enabled
5
Generate tamper on bypassed zone
No
Yes
6
Supervision options (see following table)
Disabled
Enabled
7
Disabled
Enabled
8
Generate supervision on bypassed zone
No
Yes
= Default
Содержание MG5050+
Страница 1: ...32 Zone Wireless Security System MG5050 Programming Guide ...
Страница 63: ......