4
Feature Select Programming Method
After entering certain sections, eight options will be displayed. In these instances, each option (from 1 to 8) represent a specific
feature. To turn enable the option, press the key corresponding to the desired option. Press the key again to remove the digit,
thereby, disabling the option. Press
SLEEP
to disable all eight options. When the options are set, press
ENTER
to save your settings
and advance to the next section.
Viewing Version Numbers
Decimal and Hexadecimal Programming
Table 2: Decimal and hexadecimal values for 10 and 32-Zone LED keypads
Value or Action
Key
Result
32-Zone LED
10-Zone LED
Value 0/replace current
digit with 0
SLEEP
Erase digit and remain in section
Erase digit and remain in section
Values 1 to 9
1
to
9
Zone 1 to 9
Keys
1
to
9
A (hex only)
0
Zone 10
Key
0
(10)
B (hex only)
OFF
Zone 11
OFF
C (hex only)
BYP
Zone 12
BYP
D (hex only)
MEM
Zone 13
MEM
E (hex only)
TBL
Zone 14
TBL
F (hex only)
Zone 15
Exit without saving
CLEAR
Arm and Stay LEDs flash
Arm and Stay LEDs flash
Save data (hex only)
ENTER
Advances to next section
Advances to next section
Example: Version
01.42
NOTE:
For keypads K10V/H and K636, the keypad version numbers cannot be viewed.
Table 1: Viewing panel and keypad version numbers
Step
Action
Details
When Viewing Keypad Version
1
Enter viewing mode:
• For panel version, enter section
[980]
• For
keypad version, enter installer programming,
then press and hold
ARM
The first digit is displayed
(usually
0
)
Digit 1:
ARM
is illuminated
2
Press
ENTER
The second digit is displayed
Digit 2:
SLEEP
is illuminated
3
Press
ENTER
The third digit is displayed
Digit 3:
STAY
is illuminated
4
Press
ENTER
The fourth digit is displayed
Digit 4:
OFF
is illuminated
Digits 1-4