24
Programming Guide
46
Bus/EBus/wireless module new trouble (partition 1 only)
00
Bus/EBus/wireless module communication fault
01
Tamper trouble
02
Power fail
03
Battery failure
99
Any bus module new trouble event
47
Bus/EBus/wireless module trouble restored (partition 1 only)
00
Bus/EBus/wireless module communication fault restore
01
Tamper trouble restore
02
Power fail restore
03
Battery failure restore
99
Any bus module new trouble restored event
48
Special (partition1 only)
00
System power up
01
Reporting test
02
Software log on
03
Software log off
04
Installer in programming mode
05
Installer exited programming mode
06
Maintenance in programming mode
07
Maintenance exited programming mode
08
Closing delinquency delay elapsed
13
Failed to arm
99
Any special event
49
Low battery on zone
01 to 32
Zone number
99
Any zone number
50
Low battery on zone restore
01 to 32
Zone number
99
Any zone number
51
Zone supervision trouble
01 to 32
Zone number
99
Any zone number
52
Zone supervision restore
01 to 32
Zone number
99
Any zone number
53
Wireless module supervision trouble (partition 1 only)
01 to 16
Output
17 to 18
Wireless repeater
19 to 22
Wireless keypad
27 to 30
Wireless siren
99
Any output number
54
Wireless module supervision restore (partition 1 only)
01 to 16
Output
17 to 18
Wireless repeater
19 to 22
Wireless keypad
27 to 30
Wireless siren
99
Any output number
55
Wireless module tamper trouble (partition 1 only)
01 to 16
Output
17 to 18
Wireless repeater
19 to 22
Wireless keypad
27 to 30
Wireless siren
99
Any output number
56
Wireless module tamper restore (partition 1 only)
01 to 16
Output
17 to 18
Wireless repeater
19 to 22
Wireless keypad
27 to 30
Wireless siren
99
Any output number
Table 11: List of events