28
Programming Guide
User Programming
Use the following section to program the various user features on your control panel.
System Codes
Use worksheet 17 to record your settings for the system codes. For access options, see section
[701]
, in table 23 on page 36.
NOTE:
The maintenance code cannot access the following sections:
[395]
(Installer code lock);
[397]
(Installer code);
[398]
(Maintenance code);
[815]
(Monitoring
station telephone number 1);
[816]
(Monitoring station telephone number 2);
[817]
(Backup monitoring station telephone);
[910]
(Panel ID);
[911]
(PC password);
[970]
(Download memory key into panel);
[975]
(Upload panel into the memory key).
NOTE:
The installer and system master codes may consist of four (default) or six digits (see option
1 of section [701], in table 23 on page 36). The control panel
automatically removes the last two digits of these codes, if the length is changed from six digits to four. However, if the access code length is changed from four
digits to six, the control panel adds the code’s first two digits to the end of the code.
User Code Options
Use worksheet 18 to record your settings for the user code options. See table 14 for details on these options.
NOTE:
When section [400] is accessed, the control panel will copy the saved value of that section to all user option sections ([404] to [432]).
NOTE:
The system master, master 1, and master 2 user code options cannot be modified. However, if partitioning is not enabled, the user code options for master 2
will match those of master 1.
Worksheet 17: User System Codes
Section
Data
Description
Default Setting
[395]
___/___/___
Installer code lock*
000
[397]
___/___/___/___/___/___
Installer code
0000
[398]
___/___/___/___/___/___
Maintenance code
-
[399]
___/___/___/___/___/___
System master code
1234
* Enter
147
to lock entire control panel. Once locked, enter any other three-digit combination to unlock.
Table 14: User code options
Option
Description
1
Partition 1 access
2
Partition 2 access
3
Bypass programming
4
Stay/Sleep arming
5
Force arming
6
Arm only
7
PGM activation only
8
Duress
Worksheet 18: User Code Options
Section
User
Options
Section
User
Options
[400]
Default option
1
2
3
4
5
6
7
8
[417]
User 17
1
2
3
4
5
6
7
8
[401]
System master
1
2
3
4
5
6
7
8
[418]
User 18
1
2
3
4
5
6
7
8
[402]
Master 1
1
2
3
4
5
6
7
8
[419]
User 19
1
2
3
4
5
6
7
8
[403]
Master 2
1
2
3
4
5
6
7
8
[420]
User 20
1
2
3
4
5
6
7
8
[404]
User 4
1
2
3
4
5
6
7
8
[421]
User 21
1
2
3
4
5
6
7
8
[405]
User 5
1
2
3
4
5
6
7
8
[422]
User 22
1
2
3
4
5
6
7
8
[406]
User 6
1
2
3
4
5
6
7
8
[423]
User 23
1
2
3
4
5
6
7
8
[407]
User 7
1
2
3
4
5
6
7
8
[424]
User 24
1
2
3
4
5
6
7
8
[408]
User 8
1
2
3
4
5
6
7
8
[425]
User 25
1
2
3
4
5
6
7
8
[409]
User 9
1
2
3
4
5
6
7
8
[426]
User 26
1
2
3
4
5
6
7
8
[410]
User 10
1
2
3
4
5
6
7
8
[427]
User 27
1
2
3
4
5
6
7
8
[411]
User 11
1
2
3
4
5
6
7
8
[428]
User 28
1
2
3
4
5
6
7
8
[412]
User 12
1
2
3
4
5
6
7
8
[429]
User 29
1
2
3
4
5
6
7
8
[413]
User 13
1
2
3
4
5
6
7
8
[430]
User 30
1
2
3
4
5
6
7
8
[414]
User 14
1
2
3
4
5
6
7
8
[431]
User 31
1
2
3
4
5
6
7
8
[415]
User 15
1
2
3
4
5
6
7
8
[432]
User 32
1
2
3
4
5
6
7
8
[416]
User 16
1
2
3
4
5
6
7
8
Содержание MG5050+
Страница 1: ...32 Zone Wireless Security System MG5050 Programming Guide ...
Страница 63: ......