AT-OMNI-121 / AT-OMNI-122
91
Configuration and Management Interfaces
Option
Description
None Checked
Resets the decoder with factory-default settings.
Reset User
Resets the decoder to factory-default settings and resets custom user information.
Reset Network
Resets the decoder to factory-default settings and resets network information.
Reset Defaults
Resets the decoder to factory-default settings and restores a default device configuration that
includes defined multicast addresses.
FACTORY RESET
Click this button to reset the decoder to factory-default settings. When performing a factory reset, the following
options can be selected, by clicking the check box. If no options are selected, then the decoder is reset with no
factory-default settings.
IDENTIFY
Click this button to physically identify a unit on the network. Clicking this button will cause all front-panel LED
indicators to flash for 10 seconds.
DEBUG
Click this button to instruct the unit to create a debug file. This file is used by Atlona Technical Support Engineers to
diagnose internal issues with the unit.
REBOOT
Click this button to perform a soft reboot of the decoder.
SAVE
Click this button to commit changes to the settings on this page.