AT-OMNI-121 / AT-OMNI-122
45
Device Operation
Downstream Control using Triggering
TCP/IP traffic received by an encoder or decoder, on the defined IP:Port socket, are translated to RS-232, allowing
both control of source or display. Control is achieved using a control system, where all control commands are stored.
1.
Login to the decoder and click the
Serial
menu.
2. Under the
Serial Port Configuration
window group, for the desired serial port, click the
Mode
drop-down list
and select
Serial
.
3.
Click the
SAVE
button.
1
2
3
5
4
6
7
4. Under the
Serial Configuration
window group, click the
Port
drop-down list and select the desired serial port.
5.
Click the
Mode
drop-down list and select
output
.
6. Click the
Input
drop-down list and select
not used
.
7.
Click the
SAVE
button.
Option 1: Defining Commands on the Decoder