83
Alarm Group
REC Mode:
Select the desired setting by clicking on
the radio button.
EXT:
Select this to gen-lock the unit during the alarm
recording.
INT:
Select this if the asynchronous unit is connected to
the unit. When it is activated, the drop-down menu
becomes also active so that you can select the
desired normal recording rate. 002, 004 to 128
(field) are selectable.
The factory default setting is EXT.
DYNAMIC REC:
Select the desired setting by clicking
on the drop-down menu.
ALM-PRI:
Select this to give recording priority to the
camera channel with the alarm input.
ALM-ONLY:
Select this to record the images from the
alarm-associated camera channel.
GROUP:
Select this to give recording priority to a group
of up to 4 camera channels associated to the alarm
input. When you select this, the Group Setting but-
ton becomes active. By pressing the button, the
Mux Alarm Group window will be displayed so that
you can configure the ALM 1 to 16 parameters.
(Refer to Mux Alarm Group.)
OFF:
Select this to deactivate the alarm priority mode.
The factory default setting is OFF.
• System Group
Camera SW Loss:
Select the desired setting by click-
ing on the drop-down menu.
ON:
“CAM SW LOSS” will blink on the associated moni-
tor when loss of the camera switching pulse is
detected.
OFF:
“CAM SW LOSS will not appear on the monitor.
The factory default setting is ON.
Dummy Black:
Select the desired setting by clicking
on the drop-down menu.
ON:
The black image will be displayed for a camera
channel that is not connected to the camera.
OFF:
The camera channel will be skipped in the
sequence/spot mode.
The factory default setting is ON.
(Save Exit) button
Saves the configuration and closes the Multiplexer Mode
window.
(Cancel Exit) button
Cancels the configuration and closes the Multiplexer Mode
window.
●
Mux Alarm Group
This is a submenu of the Multiplexer window. In this win-
dow, up to 4 cameras are given recording priority for each
alarm input.
• Click a drop-down menu to assign the camera numbers
(1 to 16) to each alarm input (ALM 1 to 16). The factory
default setting is same as the illustration.
• To configure ALM 9 to 16, click on the ALM 9 – 16 tab.
(Save Exit) button
Saves the configuration and closes the FS Board Alarm
Group window.
(Cancel Exit) button
Cancels the configuration and closes the FS Board Alarm
Group window.
Содержание WJSX150 - SWITCHER - ADDENDUM
Страница 8: ...9 FEATURES OF THE MATRIX SWITCHER SYSTEM ...
Страница 22: ...23 DETAILED PRODUCT DESCRIPTION ...
Страница 32: ...33 INSTALLATIONS AND SYSTEM CONNECTIONS ...
Страница 47: ...49 WJ SX150 SETUP PROCEDURES ...
Страница 85: ...87 OPERATING PROCEDURES TERMINAL MODE ...
Страница 104: ...107 OPERATING PROCEDURES PS DATA ...
Страница 111: ...115 EXPANDED FUNCTION ...
Страница 127: ...131 APPENDIX ...