68
■
Get a Configuration Data from SX150
Pressing this button will start the getting of the configuration
data from the unit to the PC.
●
How to Display
To display this window, click on the
(Get from
SX150) button in the main window (p. 65).
●
Parameters
The file name of the configuration data appears.
(OK) button
To get the configuration data from the unit to the PC, click
on this button.
(Cancel Exit) button
To cancel the getting of the configuration data from the unit
to the PC, click on this button.
Notes:
• The configuration data getting is also possible during
the surveillance, for it will not interfere with the system
operation.
• The past data will be overwritten when getting a new
configuration data.
• To change the getting directory, select it. (Refer to p. 84
Select Setup Data File.)
• When the file getting has been successfully executed,
“Completed!” will appear. If “Connection Error”
appears, confirm the connection and the serial port set-
ting of the PC and the unit. (Refer to p. 47 and p. 72.) If
“Failed!” appear, retry the file getting.
■
Tour Sequence
This window configures the parameters of tour sequences:
the operating camera, dwell time*, preset position** in each
step.
Each sequence has up to 16 steps, and up to 16
sequences are configurable.
The configuration of a tour sequence can be copied to
another one.
* the display time of a camera image
** the panning/tilting position which has been preset in
advance
Notes
:
• Enter the parameters from Step 1 in a sequential order.
If you skip a step, it will result in an error.
• After selecting a camera number, be sure to select the
dwell time, too. If you skip either of them, the message
requesting the parameter entry will appear.
●
How to Display
To display this window, click on the
(Tour Sequence)
button in the main window (p. 65). Or click on the
(Tour Sequence) button in the Group Sequence window.
●
Parameters
Cam
Selects the operating camera in each step.
The camera is selectable from Camera 1 to 16. After select-
ing Camera 1 to 16 for Cam, select the time for Dwell. To
invalidate a step, select "--" for both of Cam and Dwell.
Preset
Selects the preset position of the operating camera.
The preset position is selectable from Preset 1 to 64.
Note:
Refer to p. 93 Program Preset Position for details of
how to program preset positions.
Dwell
Selects the dwell time of the operating camera.
The dwell time is selectable from 1 to 30 seconds (by a
second). Set "--" for Dwell when you have selected "--" for
Cam.
Содержание WJSX150 - SWITCHER - ADDENDUM
Страница 8: ...9 FEATURES OF THE MATRIX SWITCHER SYSTEM ...
Страница 22: ...23 DETAILED PRODUCT DESCRIPTION ...
Страница 32: ...33 INSTALLATIONS AND SYSTEM CONNECTIONS ...
Страница 47: ...49 WJ SX150 SETUP PROCEDURES ...
Страница 85: ...87 OPERATING PROCEDURES TERMINAL MODE ...
Страница 104: ...107 OPERATING PROCEDURES PS DATA ...
Страница 111: ...115 EXPANDED FUNCTION ...
Страница 127: ...131 APPENDIX ...