●
To Record the Camera Images in Maximum
Recording Rate
The following is the description of the connection between a
recorder and this unit for the maximum-rate recording.
1. Set the unit address of the recorder to 1. Then, set the
recorder’s CAMERA GENLOCK to ON in its SETUP
MENU. (Refer to the recorder's operating instructions.)
2. Connect the unit’s CAM OUT 1 to 16 connectors to the
recorder’s VIDEO IN 1 to 16 connectors with a coaxial
cable.
3. Connect the unit’s EXT IN connector to the recorder’s
GENLOCK OUT connector with a coaxial cable.
4. Connect the unit’s DATA HDR connector to the
recorder’s DATA port with a modular cable.
(The control data and alarm signal will be output from
the unit to the recorder.)
5. After the connection, set the unit’s EXT IN to GENLOCK
ON through SETUP MENU or WJ-SX150 Administrator
Console (Refer to pp. 60 or 66).
Notes:
• You need WJ-HD500A or a newer model for the maxi-
mum-rate recording.
• The playback, multiscreen output or live images from the
recorder are not displayed on Monitor 1 to 4. To confirm
the images, you need to connect another monitor with
the recorder.
• The recorder will not operate if its unit address is set to
other than 1.
• Make sure the DATA HDR port's unit address is set to 1
through WJ-SX150 Administrator Console. (Refer to p.
66.) If another number is selected, you cannot control
the recorder.
WJ-SX150 Matrix Switcher
WJ-HD500A or a newer model
16
16
15
15
14
14
13
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
2
2
3
1
1
SIGNAL GND
10/100
BASE-T
SPOT
OUT
IN
EXT STORAGE
COPY
CONTROL
ALARM
VIDEO
MODE
DATA
REMOTE(WV-CU50)
GEN-LOCK OUT
SERIAL
IN
OUT
OUT
MULTI SCREEN OUT
AUDIO
EXT IN
GENLOCK
OUT
MULTI
SCREEN
OUT
DATA
DATA HDR
Monitor
CAMERA
1
1
2
2
3
3
2
DATA 3 DATA 2
SERIAL
ALARM
TERM
OFF
ON
4
2
1
4
3
EXT OUT
(REC OUT)
CAMERA
SW IN
RS485(CAMERA)
LINE
SELECT
MONITOR OUT
EXT IN
(PLAY IN)
OUT
IN
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
RS485(CAMERA)
PS•DATA
DATA 4
DATA HDR
DATA 1
42
Notes:
• You cannot record the camera images in maximum
recording rate through this connection. Refer to the next
connection example in this page.
• The recorder will not operate if its unit address is set to
other than 1.
Содержание WJSX150 - SWITCHER - ADDENDUM
Страница 8: ...9 FEATURES OF THE MATRIX SWITCHER SYSTEM ...
Страница 22: ...23 DETAILED PRODUCT DESCRIPTION ...
Страница 32: ...33 INSTALLATIONS AND SYSTEM CONNECTIONS ...
Страница 47: ...49 WJ SX150 SETUP PROCEDURES ...
Страница 85: ...87 OPERATING PROCEDURES TERMINAL MODE ...
Страница 104: ...107 OPERATING PROCEDURES PS DATA ...
Страница 111: ...115 EXPANDED FUNCTION ...
Страница 127: ...131 APPENDIX ...