134
Alarm ACK
(Each monitor)
CMD:HmmAK
ANS:HmmAK
mm=Monitor No.
Item
Alarm input
OAIcc
No response
cc=Alarm No.
Transmission Command
(ASCII)
Response (ASCII)
Parameter (ASCII)
Alarm reset
(Each monitor)
CMD:HmmAR
ANS:HmmAR
mm=Monitor No.
Alarm all reset
CMD:H00AR
ANS:H00AR
Alarm suspension
MAD
MADn
Transmission command toggles alarm sus-
pension ON or OFF.
n=0 OFF
n=1 ON
Alarm Control
Return to normal view*
CMD:HmmSE
ANS:HmmSE
mm=Monitor No.
*Available only in SETUP MENU
Item
Display SETUP MENU
CMD:HmmSS
ANS:HmmSS
mm=Monitor No.
Transmission Command
(ASCII)
Response (ASCII)
Parameter (ASCII)
Move the cursor leftward
CMD:AmmJL
—
mm=Monitor No.
Setup Control
Move the cursor rightward
CMD:AmmJR
—
mm=Monitor No.
Move the cursor upward
CMD:AmmJU
—
mm=Monitor No.
Move the cursor downward
CMD:AmmJD
—
mm=Monitor No.
Enter "0"
Enter "1"
CMD:AmmT0
CMD:AmmT1
—
—
mm=Monitor No.
mm=Monitor No.
Enter "2"
CMD:AmmT2
—
mm=Monitor No.
Enter "3"
CMD:AmmT3
—
mm=Monitor No.
Enter "4"
CMD:AmmT4
—
mm=Monitor No.
Enter "5"
CMD:AmmT5
—
mm=Monitor No.
Enter "6"
CMD:AmmT6
—
mm=Monitor No.
Enter "7"
CMD:AmmT7
—
mm=Monitor No.
Enter "8"
CMD:AmmT8
—
mm=Monitor No.
Enter "9"
CMD:AmmT9
—
mm=Monitor No.
SET
CMD:AmmST
—
mm=Monitor No.
ESC
CMD:AmmES
—
mm=Monitor No.
INC
CMD:AmmIN
—
mm=Monitor No.
DEC
CMD:AmmDE
—
mm=Monitor No.
NEXT
CMD:AmmNX
—
mm=Monitor No.
Available in SETUP MENU, Alarm History
and Video Loss History
PRE
CMD:AmmPR
—
mm=Monitor No.
Available in SETUP MENU, Alarm History
and Video Loss History
Содержание WJSX150 - SWITCHER - ADDENDUM
Страница 8: ...9 FEATURES OF THE MATRIX SWITCHER SYSTEM ...
Страница 22: ...23 DETAILED PRODUCT DESCRIPTION ...
Страница 32: ...33 INSTALLATIONS AND SYSTEM CONNECTIONS ...
Страница 47: ...49 WJ SX150 SETUP PROCEDURES ...
Страница 85: ...87 OPERATING PROCEDURES TERMINAL MODE ...
Страница 104: ...107 OPERATING PROCEDURES PS DATA ...
Страница 111: ...115 EXPANDED FUNCTION ...
Страница 127: ...131 APPENDIX ...