m=0
Spot Monitor
m=1
Multiscreen Monitor
m=2
Multiscreen 2 Monitor
m=0
Quad
m=1
7 divide
m=2
9 divide
m=3
10 divide
m=4
13 divide m=5
16 divide
m=
1
No. of divisions (+) m=D No. of divisions (
−
)
-54-
Item
Alarm Input
Response Command (ASCII)
APPENDIX
●
Communication Protocol
¥
Select parameters for communication between personal computers referring to Communication Port Setup on the SYS-
TEM SETUP menu on page 35.
The data format is shown below.
[STX] [ ] [ ] [ ] [ETX]
ASCII
(02H) ( ) ( ) ( ) (03H)
●
Command Table
A transmission command consists of 3 alphanumeric characters following an address. If a command requires a parameter,
add a colon (:) after the command. If it needs a second and a third parameter, insert a colon (:) between them.
If a command with a parameter has no parameter value specified, it will be processed at the underlined parameter value.
Note:
When remote controlling the Video Multiplexer by PC through the Data Port, add the unit adress to the transmission
command.
For example,
ADuu; OMS: m
(uu=01 - 16 unit number)
(1) Main Unit Operation Control
Command (ASCII)
Parameter (ASCII)
Monitor Select
OMS : m
OMS
VTR/Camera Select
OVC : m
OVC
m=0
Camera Mode
m=1
VTR Mode
Still ON/OFF
OST : m : nn
OST
m=0
Still OFF
m=1
Still ON
nn=00 All video channels specify
nn=01 - 16 Camera Number
Multiscreen Select
OTC : m
OTC
Sequence
OSQ : m
OSQ
m=0
End Sequence
m=1
Activate Sequence
Electronic Zoom
ON/OFF
OZM : m
OZM
m=0
Zoom OFF
m=1
Zoom ON
Single Spot CH Select
OCS : mm
OCS
mm=00 - 16 Camera Number
*00=Spot Input
Camera & Playback Display
Playback CH Select
OVS : mm
OVS
mm=01 - 16 Playback CH number
Alarm Reset
OAL : m
OAL
m=0
Manual Reset
m=1
Auto Reset
Alarm Log Clear
OAR
OAR
None
Sequence Mode
Select
OSE : m
OSE
m=0
SEQ1
m=1
SEQ2
m=2
SEQ3
OAI : m
OAI
m=0
1CH Alarm
:
m=F
16CH Alarm