The settings relating to Panasonic alarm protocol can be configured in this section.
Panasonic alarm protocol notification
[Panasonic alarm protocol]
Select “On” or “Off” to determine whether or not to provide notification by Panasonic alarm protocol according
to the settings for the “Alarm” and “Diag.” checkboxes of “Destination of notification” below.
–
When an alarm is detected (“Alarm”)
–
When a video loss is recovered (“Alarm”)
•
Default:
Off
Note
•
When “On” is selected, notification of the alarm occurrence will be provided to the registered destination
server addresses in order (to IP address 1 first, to IP address 8 last).
[Additional alarm area data(VMD)]
Determine whether or not to send notifications for the alarm area number of VMD alarm with the Panasonic
alarm protocol by selecting On/Off.
•
Default:
Off
[Destination port]
Select a destination port for the Panasonic alarm protocol from the following.
•
Available range:
1 - 65535
•
Default:
1818
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 995, 10669, 10670