115
<Model: WH-SXF09D3E5 WH-SXF12D6E5>
(Note)
• All parts are supplied from PHAAM, Malaysia (Vendor Code: 00029488).
• “O” marked parts are recommended to be kept in stock.
REF. NO.
DESCRIPTION & NAME
QTY.
WH-SXF09D3E5
WH-SXF12D6E5
REMARKS
1
BASE PAN
1
CWD521266
2
HOT WATER COIL-COMPLETE
1
CWB90C1051
O
3
RECEIVER
1 CWB141039
4
FLOAT (FLOW SWITCH)
1
CWB601008
O
6
FLARE NUT (3/8)
1
CWT251061
7
FLARE NUT (5/8)
1
CWT251064
9
PUMP
1 CWB532096
O
10
PACKING (O-RING) I.D 32mm
2
CWB811082
11
PACKING (O-RING) I.D 13.8mm
2
CWB811022
12
RETAINING RING D:22mm
1
CWH581007
16
BOTTLE COMPLETE
1
CWH90C0022
CWH90C0011
17
HEATER ASS'Y
1
CWA34K1014
CWA34K1020
O
18
SOUND PROOF MATERIAL
1
CWG302595
CWG302575
19
THERMOSTAT
2/3 CWA151065
O
20
ELECTRONIC CONTROLLER-MAIN
1
CWA73C5712
CWA73C5713
O
21
TERMINAL BOARD ASS'Y
1
CWA28K1217
22
TERMINAL BOARD ASS'Y
1
CWA28K1232
25
TERMINAL BOARD ASS'Y
1
CWA28K1229
26
TERMINAL BOARD ASS'Y
1
CWA28K1230
27
ELECTRO MAGNETIC SWITCH
1
K6C1AYY00004
O
28
TERMINAL BOARD ASS’Y
1
CWA28K1231
29
RESIDUAL CURRENT CIRCUIT BREAKER
2/3
CWA181005
O
30
TRANSFORMER-COMPLETE
1 CWA40C1075
O
31
SENSOR-COMPLETE
1 CWA50C2762
O
32
REMOTE CONTROL COMPLETE
1
CWA75C3656
O
33
PRESSURE GAUGE
1
CWB070001
O
34
PRESSURE RELIEF VALVE
1
CWB621011
O
35
CABINET
1 CWE001050A
36
HANDLE
2 CWE161008
37
CABINET FRONT PLATE
1
CWE061265A
38
INSTALLING HOLDER
1
CWH361103A
39
OPERATING INSTRUCTION
1
CWF567972
40
INSTALLATION INSTRUCTION
1
CWF614801
41
ACCESSORY-COMPLETE
1 CWH82C1754
42
FLARE NUT
1
CWT251063
43
FLARE NUT
1
CWT251079
Содержание WH-SXF12D6E5
Страница 10: ...10 4 Location of Controls and Components 4 1 Indoor Unit 4 1 1 Location of Control ...
Страница 11: ...11 ...
Страница 12: ...12 ...
Страница 13: ...13 4 1 2 Weekly Timer Setting ...
Страница 14: ...14 4 1 3 Setting Up The Special Functions ...
Страница 15: ...15 4 1 4 Main Components 4 2 Outdoor Unit ...
Страница 16: ...16 5 Dimensions 5 1 Indoor Unit ...
Страница 17: ...17 5 2 Outdoor Unit ...
Страница 19: ...19 ...
Страница 20: ...20 7 Block Diagram 7 1 WH UX09DE5 ...
Страница 21: ...21 7 2 WH UX12DE5 ...
Страница 22: ...22 8 Wiring Connection Diagram 8 1 Indoor Unit 8 1 1 WH SXF09D3E5 ...
Страница 23: ...23 8 1 2 WH SXF12D6E5 ...
Страница 24: ...24 8 2 Outdoor Unit ...
Страница 25: ...25 9 Electronic Circuit Diagram 9 1 Indoor Unit 9 1 1 WH SXF09D3E5 ...
Страница 26: ...26 9 1 2 WH SXF12D6E5 ...
Страница 27: ...27 9 2 Outdoor Unit ...
Страница 28: ...28 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Страница 29: ...29 10 1 2 Solar Printed Circuit Board Optional ...
Страница 30: ...30 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Страница 31: ...31 10 2 2 Capacitor Printed Circuit Board 10 2 3 Noise Filter Printed Circuit Board ...
Страница 48: ...48 Heat Tank Mode Heating priority not set Under Solar Priority Set Condition ...
Страница 49: ...49 Heat Tank Mode Heating priority not set Under Solar Priority Not Set Condition ...
Страница 57: ...57 ...
Страница 58: ...58 ...
Страница 105: ...105 17 3 To Remove Pressure Gauge 17 4 To Remove Control Panel ...
Страница 106: ...106 17 5 To Remove RCCB ELCB 17 6 To Remove Transformer and Electronic Controller Board ...
Страница 116: ...116 19 2 WH UX09DE5 WH UX12DE5 ...