211
19.2 Heating Capacity Table
19.2.1 WH-MXC09J3E8
Water Out
25ºC
35ºC
Outdoor Air
Capacity(W)
Input Power(W)
Current(A)
Capacity(W)
Input Power(W)
Current(A)
-20
9000
3440
5.1
9000
3950
5.9
-15
9000
2980
4.5
9000
3410
5.1
-7
10500
2720
4.1
9000
2920
4.4
2
10800
2140
3.2
9000
2360
3.5
7
9000
1380
2.1
9000
1770
2.6
25
9000
770
1.2
9000
1000
1.5
Water Out
45ºC
55ºC
60ºC
Outdoor Air
Capacity(W)
Input
Power(W)
Current(A)
Capacity(W)
Input
Power(W)
Current(A)
Capacity(W)
Input
Power(W)
Current(A)
-20
9000
4650
6.9
7900
5580
8.3
-
-
-
*
-15
9000
4040
6.0
9000
4830
7.2
8700
5370
8.0
-7
9000
3540
5.3
9000
4240
6.3
9000
4620
6.9
2
9000
2910
4.3
9000
3550
5.3
9000
4050
6.1
7
9000
2370
3.5
9000
2920
4.4
9000
3290
4.9
25
10000
1670
2.5
10000
2280
3.4
11000
2860
4.3
Note:
* Between outdoor ambient -15°C and -20°C, the water outlet temperature gradually decreases from 60°C to 55°C.
* Only when ΔT is set to 15°C, the set temperature above 60°C will take effect.