57
Optional cables:
•
External control cable
•
Tank sensor cable
•
Room sensor zone 1
•
Outdoor air sensor cable
•
Tank OLP cable
•
Power Supply 1 cord
Apply cut
Bushing
x 6
•
Power Supply 2 cord
•
Remote controller cable
Optional cables:
•
3-way valve cable
•
2-way valve cable
•
Room thermostat zone 1 cable
•
Booster heater cable
•
Extra pump cable
•
Boiler contact cable /
Defrost signal cable
How to guide optional cables and power supply cords to Bushing
15
15
A
L
N
L1
WARNING
ABCDEFGHJMFLG
ABCDEFGHJMFLG
ABCDEFGHJMFLG
ABCDEFGHJMFLG
2
Y
L
P
P
U
S
R
E
W
O
P
1
Y
L
P
P
U
S
R
E
W
O
P
N1
B
CAUTION
240-250V
L
1
POWE R SUP PLY 2
N
1
Bind all lead
wires with
these bands
PCB
Power supply 2
RCCB
Bind all lead wires
with these bands
Power supply 1
RCCB
Holder
(Clamper)
•
Power Supply 1 cord
•
Power Supply 2 cord
Optional cables:
•
3-way valve cable
•
2-way valve cable
•
Room thermostat zone 1 cable
•
Booster heater cable
•
Extra pump cable
•
Boiler contact cable /
Defrost signal cable
•
Remote controller cable
For WH-MXC12J9E8
and WH-MXC16J9E8
For WH-MXC09J3E8
Optional cables:
•
External control cable
•
Tank sensor cable
•
Room sensor zone 1
•
Outdoor air sensor cable
•
Tank OLP cable
How to guide optional cables and power supply cords
(view without internal wiring)
1
For connection to optional PCB
□
4
1 By connecting optional PCB, 2 Zone temperature control can be achieved. Please connect mixing valves,
water pumps and thermistors in zone 1 and zone 2 to each terminals in optional PCB.
Temperature of each zone can be controlled independently by remote controller.
2 Pump zone 1 and zone 2 cable shall be (2 x min 1.5 mm
2
), of type designation 60245 IEC 57 or heavier.
3 Solar pump cable shall be (2 x min 1.5 mm
2
), of type designation 60245 IEC 57 or heavier.
4 Pool pump cable shall be (2 x min 1.5 mm
2
), of type designation 60245 IEC 57 or heavier.
5 Room thermostat zone 1 and zone 2 cable shall be (4 x min 0.5 mm
2
), of type designation 60245 IEC 57 or
heavier.
6 Mixing valve zone 1 and zone 2 cable shall be (3 x min 1.5 mm
2
), of type designation 60245 IEC 57 or
heavier.
7 Room sensor zone 1 and zone 2 cable shall be (2 x min 0.3 mm
2
), double insulation layer (with insulation
strength of minimum 30V) of PVC-sheathed or rubber-sheathed cable.
8 Buffer tank sensor, pool water sensor and solar sensor cable shall be (2 x min 0.3 mm
2
), double insulation
layer (with insulation strength of minimum 30V) of PVC-sheathed or rubber-sheathed cable.