16
Item
Unit
Water System
Performance Test Condition
EN 14511 / EN 14825
POS (EAN)
5025232910700
Operation Range
Outdoor Ambient
°C (min. / max.)
Cooling: 10 / 43
Heating: -20 / 35
Water Outlet
°C (min. / max.)
Cooling: 5 / 20
Heating (Circuit): 20 / 55 (Below Ambient -20°C) *
3
20 / 60 (Ambient -15 ~ 0°C or
Above Ambient 25°C) *
3
20 / 65 (Ambient 5 ~ 20°C) *
3
*
4
Internal Pressure Differential
kPa
Cooling: 55
Heating: 55
Water Pipe Diameter
Inlet
inch
1-1/4
Outlet
inch
1-1/4
Water Drain Hose Inner Diameter
mm (inch)
15.00 (19/32)
Pump
Motor Type
DC Motor
Input Power
W
173
Hot Water Coil
Type
Brazed Plate
No. of Plates
38
Size (H x W x L)
mm
71.4 x 121 x 333
Water Flow Rate
l/min (m³/h)
Cooling: 34.4 (2.1)
Heating: 34.4 (2.1)
Pressure Relief Valve Water Circuit
kPa
Open: 300, Close: 266 and below
Flow Switch
Type
Electronic Sensor
Protection Device
A
Residual Current Circuit Breaker (25)
Residual Current Circuit Breaker (25)
Expansion Vessel
Volume
l
10
MWP
bar
3
Capacity of Integrated Electric Heater
kW / °C
9.00
Note:
Cooling capacities are based on outdoor air temperature of 35°C Dry Bulb with controlled indoor water inlet
temperature of 12°C and water outlet temperature of 7°C.
Heating capacities are based on outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb
(42.8°F Wet Bulb) with controlled indoor water inlet temperature of 30°C and water outlet temperature of 35°C.
Specification are subjected to change without prior notice for further improvement.
Flow rate indicated are based on nominal capacity adjustment of leaving water temperature (LWT) 35°C and
ΔT 5°C
The unit will restart automatically after the outdoor temperature returns to the specified range.
*
3
Between outdoor ambient -15°C and -20°C, the water outlet temperature gradually decreases from 60°C to
55°C.
*
3
Between outdoor ambient 5°C and 0°C, the water outlet temperature gradually decreases from 65°C to 60°C.
*
3
Between outdoor ambient 20°C and 25°C, the water outlet temperature gradually decreases from 65°C to
60°C.
*
4
Only when ΔT is set to 15
°
C, the set temperature above 60
°
C will take effect.