12.14 Solar Operation (Optional)
12.14.1 Solar Operation:
1 External solar heat source signal can be connect to unit for proper control of heat source switching during
tank boiling time.
2 Control according to preset whether solar priority is set or not.
3 When tank connection is NOT set at SETTING mode, solar operation is disabled.
4 When Pump A (from solar pump station) is detected On through connection Y3 and Y4, then the Solar pump
3 Way Valve is requested ON (Refer to figure below).
12.14.2 Solar Operation Control
When solar priority is SET
1 Operation
condition:
a 3 way valve operates if all of the following conditions are fulfilled:
Power On. (regardless operation ON or OFF)
There is operation request from solar pump station.
Tank hot water temp is below solar on upper limit temp 72°C.
2 Stop
condition:
a 3 way valve stops operating when:
No power supply to unit
OR
There
is
NO
operation request from solar pump station
OR
Tank hot water temp is above solar off upper limit temp 80°C.
* heat pump OFF OR operate to room side when solar pump operate during solar priority set.
* booster heater OFF when solar pump operate during solar priority set.
When solar priority is NOT SET
1 Operation
condition:
a 3 way valve operates if all of the following conditions are fulfilled:
Power On. (regardless operation ON or OFF)
There is operation request from solar pump station.
Tank hot water temp is below solar on upper limit temp 72°C.
Heat pump thermo OFF in tank mode OR Heat pump operate to room side
(during operation ON and tank mode selected).
2 Stop
condition:
a 3 way valve stops operating when:
No power supply to unit
OR
There
is
NO
operation request from solar pump station
OR
Tank hot water temp is above solar off upper limit temp 80°C.
Heat pump thermo ON and operate to tank side. (during operation ON and tank mode selected)
Solar Pump Station
Tank
R
IN
R
OUT
Pump A Operation
Signal Output
Tank temperature sensor
for Solar pump station (Ø 8mm)
OLP
TM200
PWR
Pump A Operation
Signal Input
communication
cable
SO
L
A
R
SO
L
A
R
Y
3
Y
4
R
OUT
R
IN
E
E
E
AC230V
Solar pump 3 way
Valve
AC230V
SCB
Connecting diagram with the Solar Pump Station