Water Inlet Thermo Condition
o
Heat pump THERMO OFF TEMP:
1. Water inlet temperature > 65°C for continuous 60 seconds, heat pump OFF.
o
Heat pump THERMO ON TEMP:
1. Heat pump THERMO ON TEMP = Water inlet temperature < 65°C.
Booster heater control
o
Booster heater turns ON and OFF follow normal operation.
o
Booster heater turns ON condition:
1. During start up time (initialization), Booster heater turns ON after DELAY TIMER.
2. When tank temperature lower than HEATER ON TEMP.
3. 20 minutes from previous heater OFF.
o
Booster heater turns OFF CONDITION:
1. When tank temperature higher than tank set temperature for continuous 15 seconds.
Solar 3-way valve
o
Solar pump operates follow solar operation specification.
2 way valve closes
Other
o
Indoor backup heater cannot be ON during tank mode only.
Tank mode
Tank side
Tank Thermo OFF
3 way valve
Tank set Temp. = 65°C
Heat Pump
Booster Heater
ID Water Pump
Booster Heater
Delay Time
on
off
on
off
on
off
on
off