32
●
Setting functions during operation
CAUTION
The motor and motor load fluctuation could change significantly and the motor
may suddenly start or stop when data is being changed during operation.
(Before making changes, ensure personal safety at all times.)
Failure to do so could lead to injury.
[Parameters that can be changed during operation]
Parameter P01, P02
: 1st acceleration/deceleration time
Parameter P05, P42
: Torque boost level/2nd torque Boost level
Parameter P29 to P31 : Jog frequency, acceleration/deceleration time
Parameter P32 to P38 : Preset frequency 2 to 8
Parameter P39, P40 : 2nd acceleration/deceleration time
Parameter P56, P57
: Bias/Gain frequency
Parameter P59
: Analog, PWM output compensation
Parameter P61
: Line speed multiplier
Parameter P64
: Carrier frequency
Note)
0V stop may occur if the "preset frequency 2 to 8 is set to 000", the
"bias frequency is set to 0Hz or less" or the "gain frequency is set to
000".
(When changing the above data or changing to the above data, the
motor will start and stop simultaneously with the setting of the data, so
always ensure surrounding safety.)