63
SETTING DATA CLEAR (Parameter P66)
The set data can be changed to the factory setting data in a batch.
Data setting range
Details
0
Data value that indicates normal state.
1
Changes all data to the factory settings.
Note)
When "1" is displayed and the SET button is pressed, the display will automatically
change to "0" after the data is changed, and the changing procedure will be
completed.
FAULT DISPLAY 1 to 4 (Parameter P67 to P70)
Up to four causes of trips are saved even when the power is turned OFF.
The details of the faults can be confirmed with parameter P67 (latest fault details), P68
(previous fault details), P69 (second to last fault details) and P70 (third to last fault details).
Note)
See "Individual Details and Remedies for Fault Trips" on page 74 for details on the
faults.