Operating with the operation panel - 1 (Factory setting state)
·
Forward/reverse run operation:
Start/stop, rotation direction mode setting
(Parameter P08=0)
·
Frequency setting: Potentiometer setting (Parameter P09=0)
[Changing the rotation direction during operation]
Use the same procedures as [Changing the rotation direction] explained
above.
In this case, when the SET button is pressed last the display will change to
the output frequency display, the motor will decelerate and then will start
rotating in the reverse direction.
STOP
RUN
Power ON
The main display lamp will turn ON.
[Example for rotating in forward direction at operating frequency 25Hz]
Stop
command
Press the STOP button.
The motor will start to decelerate and will stop in
approx. 2.5 seconds.
[Stopping operation]
Gradually turn the frequency setting dial clockwise.
The motor will start rotating, and will reach 25Hz
operation when 25.0 is displayed.
Run
command
Press the RUN button.
The run state will be entered, but as the frequency setting
dial is set to Min., the 0V stop state will be entered.
Frequency
setting
Changing
the rotation
direction
Press the MODE button.
Press the SET button. (The main display will flicker)
MODE
SET
Press the
(up) button. (The main display will flicker)
Press the SET button to set the data.
SET
[Example for rotating in reverse direction at operation frequency 25Hz]
Power ON
The main display lamp will turn ON.
Press the MODE button.
MODE
Run
command
Press the RUN button.
The run state will be entered, but as the frequency setting
dial is set to Min., the 0V stop state will be entered.
RUN
Main display
0
0
0
0
0
0
2
5. 0
0. 0
r
F
0
0
0
0
0
0
r
d
F
L
r
L
0. 0
Carry out in the same manner as forward rotation [Frequency setting]
⇒
[Stop command]