background image

Pa ss i o n at e ly   P o w e r e d

Plugreen 

Solar Micro-Inverter Systems

PGM-200P-230 

PGM-230P-230 

PGM-260P-230 

Plugreen Corporation, 

Laattakatu 13, 08150 Lohja, Finland

Phone : +358 40 1525086

www.plugreen.com

[email protected]

Installation and Operations Manual

Contact Information

Содержание PGM-200P-230

Страница 1: ...lar Micro Inverter Systems PGM 200P 230 PGM 230P 230 PGM 260P 230 Plugreen Corporation Laattakatu 13 08150 Lohja Finland Phone 358 40 1525086 www plugreen com support plugreen com Installation and Operations Manual Contact Information ...

Страница 2: ... suitable copper wire 5 Step 6 Completing the Plugreen Installation Map and Connecting the PV Modules 6 4 5 Ground Fault 8 Other Faults 8 Troubleshooting an Inoperable Solar micro inverter 8 Disconnecting the Plugreen Solar micro inverter from the PV Module 9 6 Technical Considerations 10 Technical Specifications 10 Plugreen Solar micro inverter Operating Parameters 10 Voltage and Frequency Limits...

Страница 3: ... Do not attempt to repair the Plugreen Solar micro inverter it contains no user serviceable parts If it fails please contact Plugreen customer service to obtain an RMA number and start the replacement process Tamperingwith oropeningthePlugreenSolarmicro inverterwillvoid thewarranty Before installing or using the Plugreen Solar micro inverter please read all instructions and cautionary markings in ...

Страница 4: ...er supply to this unit is universal so it works from 85 to 265VAC This unit needs to be installed indoors Once you connect the AC power connect Ethernet cable between the units and your broadband router or modem Once you install the Communication Gateway unit it automatically starts communicating with the centralized web server Please log in to the data monitoring web server though Plugreen webpag...

Страница 5: ...lugreen Solar micro inverter and on the photovoltaicarray Perform all electrical installations in accordance with all local electrical codes and the NationalElectricalCode IEC Connect the Plugreen Solar micro inverter to the electrical utility grid only after receivingpriorapprovalfromtheutilitycompany Be aware that only qualified personnel should connect the Plugreen Solar micro invertertotheelec...

Страница 6: ...e system using suitable copper wire Connect the PV modules to solar micro inverters STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 Refertheinstallationdiagrambelowforbetterunderstanding Do not connect Plugreen Solar micro inverters to the utility grid or energize the AC circuit s until you have completed all of the installation procedures as described in the following sections WARNING 4 Copyright Plugr...

Страница 7: ... inverter on the common cable Each Solar micro inverter comes with one 3 pin Circular AC connector with a wire length of 60cms Connect these AC connectors with the respective female connectors on the AC Common Cable Unused connectorsontheAC CommonCableshouldbeplugged with theCapprovided AC Common Cable wiring is as Red Phase black neutral green earth ground Make sure protective end caps have been ...

Страница 8: ...lationmapsandexamplesfromwww plugreen com After Plugreen creates a graphical representation of your PV system on the website use the Plugreen website Insight application link to view detailed performance information for your PV system Please go to www plugreen com for more information on the Plugreen Insight web based monitoring and analysis ToconnectyourPVmodules Completely install all solar micr...

Страница 9: ...stem will start producing power after 3 minutesofSystemconfigurationthem Since Plugreen solar micro inverters are powered by PV panels make sure that sufficient sunlightisavailableduring thisprocess The Plugreen solar micro inverters will start to send performance data over Power Line PLC to the Communication Gateway unit The time required for all the solar micro inverters in the system to report ...

Страница 10: ...sconnect the PV wire connectors under load Please cover the PV module using anopaquecoveringsheetpriortodisconnectingthemodule Always disconnect AC power before disconnecting the PV module wires from the Plugreen Solar micro inverter The AC connector of the first solar micro inverterin a branch circuit is suitable as a disconnecting means once the AC branch circuit breaker in the load centre has b...

Страница 11: ...ntenance Disconnecting the Plugreen Solar micro inverter from the PV Module To ensure that the solar micro inverter is not disconnected from the PV modules under load adhere to the following disconnection steps in the order shown Disconnect the AC by opening the branch circuit breaker Disconnect the first AC connector in the branch circuit Cover the module with an opaque cover Using a DC current p...

Страница 12: ...ge is within the specs of solar micro inverterunits Make sure that the maximum short circuit current of PV panels should be less or equaltothesolarmicro inverterspecs Note PV module output voltage and current depends on the size and temperature of the PV cells alsothesolarirradiationfallingoverthepanels A listofcompatiblePVmodulesismaintainedonthePlugreenwebsite www Plugreen com Technical Specific...

Страница 13: ...s A Hz Hz Hz 0 95 211 49 4 49 2 2 5 4 0 1 0 99 230 85 1 1 1 50 60 1 264 50 41 50 6 Miscellaneous Operating Parameters Peak inverter efficiency CEC weighted efficiency Nominal MPP tracking efficiency Total Harmonic Distortion Operating temperature range Storage temperature range Deg C Deg C 40 40 95 92 99 5 65 65 Plug Green Micro Inverter Operating Parameters Dimensions Weight Enclosure environment...

Страница 14: ...ment of Defective Product If Plugreen repairs or replaces a Defective Product the Limited Warranty continues on the repaired or replacement product for the remainder of the original Warranty Period or ninety 90 days fromthedateofPlugreen sreturnshipmentoftherepairedorreplacementproduct whicheverislater The Limited Warranty covers both parts and labor necessary to repair the Defective Product but d...

Страница 15: ...s not apply to and Plugreen will not be responsible for any defect in or damage to any Plugreen Solar Micro inverter 1 that has been misused neglected tampered with altered or otherwise damaged either internally or externally 2 that has been improperly installed operated handled or used including use under conditions for which the product was not designed use in an unsuitable environment or use in...

Страница 16: ...g without limitation any economic losses of any kind any losses or damage to property or any personalinjury To the extent any implied warranties are required under applicable law to apply to the Plugreen Solar Micro inverter such implied warranties shall be limited in duration to the Warranty Period to the extent permitted by applicable law Some countries states or provinces do not allow limitatio...

Страница 17: ...r N S W E Stick Solar Micro Inverter sticker N S W E Stick Solar Micro Inverter sticker N S W E Stick Solar Micro Inverter sticker N S W E Stick Solar Micro Inverter sticker N S W E Stick Solar Micro Inverter sticker N S W E Stick Solar Micro Inverter sticker N S W E Stick Solar Micro Inverter sticker N S W E Stick Solar Micro Inverter sticker N S W E Stick Solar Micro Inverter sticker N S W E Sti...

Страница 18: ...Plugreen Corporation Laattakatu 13 08150 Lohja Finland Phone 358 40 1525086 www plugreen com support plugreen com Contact Information Passionately Powered ...

Отзывы: