71
7. Frequency signal changeover input function (Parameters: P19, P20, P21/Data setting
value: 6)
The frequency setting signal can be changed between the "external potentiometer" and
"parameter P09 selection signal".
<<Example>>
When SW1 (parameter P19=6) is set to frequency changeover
1
2
3
7
+
-
0 to 5
V,
0 to 10
V
External potentiometer
1
2
3
7
+
-
4 to 20mA
External potentiometer
R
Note)
Always connect the
resistor R (200
Ω
)
8. 2nd characteristic selection function (Parameters: P19, P20, P21/Data setting value: 7)
The acceleration time, deceleration time, torque boost and base frequency can be
changed to the 2nd characteristics with the switch signal from an external source.
Changeover switch OFF
Changeover switch ON
O
per
ation
char
acter
istics
·
1st acceleration time
(parameter P01)
·
1st deceleration time
(parameter P02)
·
Torque boost level
(parameter P05)
·
Base
frequency
(parameter P16)
O
per
ation
char
acter
istics
·
2nd acceleration time
(parameter P39)
·
2nd deceleration time
(parameter P40)
·
2nd torque boost level
(parameter P42)
·
2nd base frequency
(parameter P41)
Note)
Provide sufficient safety means when changing the characteristics.