51
2nd BASE FREQUENCY (Parameter P41)
Used to set the 2nd base frequency selected with
2nd characteristics select switch.
Data setting range
(Hz)
45.0 to 250
Note)
The maximum output frequency will be the
value set in parameter P03 (frequency
range) or parameter P15 (max. output
frequency).
2nd TORQUE BOOST LEVEL (Parameter P42)
Used to set the 2nd torque boost level selected with 2nd characteristics select switch.
Data setting range
0 to 40 (The output voltage will increase and the boost level
will increase when a larger value is set.).
Max. output
frequency (P15)
2nd base frequency
Output frequency (Hz)
Out
put
vol
tage (%
)
0
100
[Constant torque mode] [Square torque mode]
(Parameter P04: 0) (Parameter P04: 1)
100
0
Out
put
vol
tage (%
)
Boost
level
Output
frequency (Hz)
Base
frequency
0
100
Out
put
vol
tage (%
)
Boost
level
Output
frequency (Hz)
Base
frequency