26
●
●
●
●
Operating with the operation panel - 2
·
Forward/reverse run operation:
Forward run/reverse run (Parameter P08=1)
·
Frequency setting: Potentiometer setting (Parameter P09=0)
[Monitoring and setting the potentiometer frequency command before
operation]
Power ON
Gradually turn the frequency setting dial clockwise.
The motor will start rotating, and will reach 25Hz operation
when 25.0 is displayed.
Forward
run setting
Press the (up) button, and set the rotation direction to
forward run. (Press the button to set reverse run.)
·
Current state (0: Stop, F: Forward run, r: Reverse run)
·
Set rotation direction (F: Forward run, r: Reverse run)
Run
command
Press the RUN button.
The run state will be entered, but as the frequency setting dial
is set to Min., the 0V stop state will be entered.
RUN
The main display lamp will turn
[Example for rotating in forward direction at operating frequency 25Hz]
[Example to set operating frequency to 50Hz]
Changing
the
frequency
Turn the frequency setting dial clockwise, and set to the
Max. position. The motor speed will increase and reach
50Hz in approx. 2.5 seconds.
[Stopping operation]
Stop
command
Press the STOP button.
The motor will start to decelerate and will stop in approx. 5
seconds.
STOP
Frequency
setting
Main display
2
5. 0
F
0
0. 0
0 0
0
5
0. 0
0
0 0
Turn the frequency setting dial clockwise, and set the
frequency command to 25Hz.
Checking
and setting
the
operat-ing
frequen-cy
MODE
SET
Press the MODE button.
MODE
Preparing
for operation
Press the MODE button four times.
(Fr
⇒
dr
⇒
P01
⇒
000)
Press the SET button and check the frequency command.
Power ON
The main display lamp will turn ON.
Carry out [Forward run setting]
⇒
[Run command] explained above.
0 0
0
F r
0. 0
2
5. 0
0 0
0
0