28
●
●
●
●
Operating with the operation panel - 3
·
Forward/reverse run operation:
Start/stop, rotation direction mode setting
(Parameter P08=0)
·
Frequency setting: Digital setting (Parameter P09=1)
[Changing the frequency with the and buttons during operation
(MOP function)]
The operating frequency can be changed with the and buttons during
operation.
·
If the (up) button is held down, the operating frequency will increase.
·
If the (down) button is held down, the operating frequency will
decrease.
Note)
Once the operating frequency is determined, press the MODE
button and then press the SET button twice to set the operating
frequency.
If this is not carried out, this frequency will not be saved when the
power is turned OFF.
Main display
2
5. 0
r
0
0
0
0
0
0
F
0
0.
5
0
0
0
2
5. 0
5
0.
0
r
F
2
5. 0
5
0.
0
Power ON
Frequency
setting
Press the MODE button.
Run
commnad
Press the SET button. (The main display will flicker)
The main display lamp will turn ON.
[Example for rotating in forward direction at operating frequency 25Hz]
Stop
command
Press the STOP button.
The motor will start to decelerate and will stop in approx. 5
seconds.
STOP
MODE
SET
Press the (up) and (down) buttons to display 25Hz on
the main display.
(The main display will flicker)
Press the SET button to set the data.
SET
Press the RUN button. The factory setting is forward run, so
the motor will start rotating in the forward direction, and will
reach 25Hz operation in approx. 2.5 seconds.
RUN
[Example for rotating in forward direction at operating frequency 50Hz]
Changing
the
fre-quency
during
operation
Press the MODE button.
Press the SET button. (The main display will flicker)
Press the (up) and (down) buttons to display 50Hz on
the main display.
(The main display will flicker)
Press the SET button to set the data.
The display will change to the output frequency, and will reach
50Hz in approx. 2.5 seconds.
[Stopping operation]
MODE
SET
SET