24
2. Forward/reverse run operation
1) Forward run/reverse run method (Parameter P08 set to "1")
Press
the button (forward run) or button (reverse run) on the panel
to select the rotation direction. Operation will start when the RUN button
is pressed, and will stop when the STOP button is pressed.
∗
The inverter will not start running just by pressing the RUN button.
∗
The MOP function cannot be used if the frequency is set with the
digital method.
2) Start/stop, rotation direction mode setting method (Parameter P08 set to
"0")
First, press the MODE button twice to enter the rotation direction setting
mode. Press the SET button to display the rotation direction data,
change the rotation direction with the (up) button and (down) button,
and then press the SET button to enter the data. (Forward run is set as
the factory setting.)
Operation will start when the RUN button is pressed, and will stop when
the STOP button is pressed.
3. Combination of "MOP function", "rotation direction setting mode",
and forward/reverse run operation
Forward/reverse run operation
MOP function
Details of rotation direction
setting mode
Forward run/reverse run method
× (Cannot be used)
Only monitor function
Start/stop, rotation direction mode
setting method
{
(Can be used)
Monitor function and direction setting
Note)
When the forward/reverse run operation is set to "forward run/
reverse run method", the MOP function cannot be used even if the
frequency is set with the digital method.