65
z
To enable external control by an external switch or PLC, follow the
procedure below.
(1) Enabling external control for start/stop and forward/reverse
.......................(Parameter
P08)
(To change parameter P08 from "0" to "2")
[Changing procedure]
[Terminal connection (P08=2)]
Changing from Local Control to
External Control
[Terminal connection (P09=4)]
ON :
Reverse
run
OFF : Stop
ON :
Reverse
OFF : Forward
Common termional
ON :
Forward
run
OFF : Stop
<<When P08 = 3, 5>>
3
5
6
ON :
Start
OFF : Stop
3
5
6
Common termional
Press the STOP button to stop the inverter.
Press the SET button and set the data.
∗
This completes setting the data.
STOP
Press the MODE button three times.
Change from P01 to P08 using the ••
buttons.
•
・
•
Press the SET button.
Change from "0" to "2" using the ••
buttons.
•
・
•
(2) Enabling external control for frequency setting signals
(0 to 10V)
....................(Parameter P09)
(To change parameter P09 from "0" to "4".)
Press the SET button and set the data.
Press the SET button.
Change from "0" to "4" using the ••
buttons.
•
・
•
Press the MODE button.
1
2
3
+
-
4 to 20mA
∗
Operation can be started when the data has been set.
[O
th
er sig
n
al
c
onne
c
tions
]
<<Potentiometer
:
P09
=
2>>
10k
Ω
,
1/4W
(
Min
)
2
3
<<0 to 5V
:
P09
=
3>>
0 to 5V
+
-
2
3
<<4 to 20mA
:
P09
=
5>>
200
Ω
(Important)
When using the 4 to 20mA
signal, always connect a "200
Ω
resistor". The inverter could be
damaged if the 200
Ω
resistor is
not connected.
0
0 0
1
0
P
0
8
0
P
2
9
0
P
Main display
0
4
0
1
P
0
0 0
2
3
+
-
0 to 10V
MODE
SET
SET
SET
SET
MODE