29
●
●
●
●
Operating with the operation panel - 4
·
Forward/reverse run operation:
Forward run/reverse run (Parameter P08=1)
·
Frequency setting: Digital setting (Parameter P09=1)
1. Carry out the same operation as "Operating with the operation panel - 2" for
forward run/reverse run, stopping.
2. Carry out the same operations as "Operating with the operation panel - 3"
to set and change the frequency.
Note 1)
The rotation direction cannot be set with the "rotation direction setting
mode (dr)" in this Operating with the operation panel - 4. In the
"rotation direction setting mode (dr)", only the rotation direction and
local/external operation control state can be monitored.
Note 2)
The MOP function cannot be used with this Operating with the
operation panel - 4.
Main display
r
F
0
0
0
r
d
F
L
r
L
5
0.
0
r
F
r
d
r
L
F
L
5
0. 0
0. 0
Reverse run
Forward run
5
0. 0
0
0
0
[Continued from previous page, Example to rotate in reverse at operating frequency 50Hz]
Changing
the
rotation
direction
Press the MODE button.
Press the SET button. (The main display will flicker)
MODE
Press the
(up) button. (The main display will flicker)
Press the SET button to set the data.
Press the MODE button.
Run
command
Press the RUN button.
As the frequency is already set to 50Hz, the motor will start
rotating in the reverse direction and will reach 50Hz in approx. 5
seconds.
[Example to change to forward rotation during reverse rotation]
Press the MODE button.
Press the SET button. (The main display will flicker)
Press the (down) button. (The main display will flicker)
Press the SET button.
The motor will decelerate, and will start forward
rotation at 50Hz.
Press the MODE button.
Press the STOP button.
The motor will start to decelerate and will stop in approx. 5
seconds.
[Stopping operation]
MODE
SET
SET
RUN
SET
SET
MODE
MODE
Changing
the
rotation
direction
Stop
command
STOP