![Panasonic SF4B-F31G(V2) Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/panasonic/sf4b-f31g-v2/sf4b-f31g-v2_instruction-manual_3900092083.webp)
83
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
Common specifications
Type
10mm pitch type
20mm pitch type
40mm pitch type
Model No.
SF4B-F
□
G<V2>
SF4B-H
□
G<V2>
SF4B-A
□
G<V2>
Detecting capability
(Min. sensing object)
ø14mm opaque object
ø25mm opaque object
ø45mm opaque object
Effective aperture
angle (EAA)
±2.5 degree or less [for sensing range exceeding 3m (Required by IEC 61496-2, ANSI/UL 61496-2)]
Supply voltage
24V DC±10% Ripple P-P10% or less
Control output
(OSSD 1 / 2)
PNP open-collector / NPN open-collector transistor (switching type)
<For PNP output>
•
Maximum source current: 200mA
•
Applied voltage: Same as supply voltage
(between the control output and +V)
•
Residual voltage: 2.5V or less
(source current 200mA, when using 20m length cable)
•
Leakage current: 0.1mA or less
(Including power supply OFF condition)
•
Maximum load capacity: 0.22µF
(No load to maximum output current)
•
Load wiring resistance: 3Ω or less
<For NPN output>
•
Maximum sink current: 200mA
•
Applied voltage: Same as supply voltage
(between the control output and 0V)
•
Residual voltage: 2.5V or less
(sink current 200mA, when using 20m length cable)
•
Leakage current: 0.1mA or less
(Including power supply OFF condition)
•
Maximum load capacity: 0.22µF
(No load to maximum output current)
•
Load wiring resistance: 3Ω or less
Operation mode
(Output operation)
ON when all beams are received, OFF when one or more beams are interrupted (Note 1, 2)
(OFF when fault occurs in the sensor to the synchronization single error, too)
Protection circuit
(Short-circuit)
Incorporated
Response time
In normal operation...OFF response: 14ms or less, ON response: 80 to 90ms
Auxiliary output
(Non-safety output)
PNP open-collector transistor / NPN open-collector transistor (switching type)
<For PNP output>
•
Maximum source current: 60mA
•
Applied voltage: Same as supply voltage
(between the auxiliary output and +V)
•
Residual voltage: 2.5V or less
(source current 60mA, when using 20m length cable)
<For NPN output>
•
Maximum sink current: 60mA
•
Applied voltage: Same as supply voltage
(between the auxiliary output and 0V)
•
Residual voltage: 2.5V or less
(sink current 60mA, when using 20m length cable)
Operation mode
(Output operation)
When OSSDs are ON: OFF, when OSSDs are OFF: ON (factory setting)
[Changeable by using the handy controller (
SFB-HC
) (optional).]
Protection circuit
(Short-circuit)
Incorporated
Protection
IP65 and IP67(IEC)
Degree of pollution
3
Ambient temperature
-10 to +55°C(No dew condensation ot icing allowed), Storage:-25 to +70°C
Ambient humidity
30 to 85%RH, Strage: 30 to 95%RH
Ambient illuminance
Incadescent lamp: 3,500ℓ
x or less at the light-receiving surface
Altitude for use
2000m or less above sea level (Note 3)
Voltage withstandability
1,000V AC for one min. (between all supply terminals connected together and enclosure)
Insulation resistance
20MΩ or more with 500V DC mega (between all supply terminals connected together and enclosure)
Vibration resistance
10 to 55Hz frequency, 0.75mm amplitude in X, Y, and Z directions for two hours each
Shock resistance
300m/s
2
acceleration (Approx. 30G) in X, Y and Z directions for three times each
SFF (Safe failure fraction)
99%
HFT (Hardware
failure tolerance)
1
Sub system type
Type B (IEC 61508-2)
Mission time
20 years
Emitting element
Infrared LED (Peak emission wavelength: 870nm)
Connection method
Connection with connectors
Cable extension
Extension up to total 50m is possible for both emitter and receiver connecting cable (optional) (Note 4)
Material
Enclosure: Aluminum, Upper / lower case: Aluminum, Sensing surface: PC / Polyester resin, Cap: PBT
Accessory
MS-SFB-2
(Intermediate sup-
porting bracket): (Note 5)
SF4B-TR14
(Test rod): 1 pc.
MS-SFB-2
(Intermediate sup-
porting bracket): (Note 5)
SF4B-TR25
(Test rod): 1
MS-SFB-2
(Intermediate
supporting bracket): (Note 5)
Applicable standard
EN 61496-1 (Type 4), EN 55011, EN 61000-6-2, EN
50178, EN ISO 13849-1: 2008 (Category 4,PLe)
IEC 61496-1/2 (Type 4) ISO 13849-1: 2006 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
ANSI/UL 61496-1/2 (Type 4), UL 1998 (Class 2)