25
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
2-4-3 Extension and Dismantling of Sensor (Series Connection)
This section describes the extension method of the series connection using the options.
For constructing the series connection, the following procedure is required.
●
Do not lose any screws during extension / dismantling work.
●
Furthermore, do not mix emitters and receivers to mount in series connection.
●
The packing is attached to the connector of the cable for a series connection.If
the packing is not attached correctly, reattach the packing as shown in the fig
-
ure below, and mount to this device.
<Mounting method of cable for series connection>
Replace the cable for series connection (
SFB-CSL□
).
1. Loosen the two M2.6 screws of the end cap on the main sensor (emitter and receiver to
which the synchronization line has been connected), and then remove the end cap from the
device.
2. Insert the connector of the cable for series connection (
SFB-CSL□
) (optional) into the con-
nector. When inserting the connector, fit the cable into the groove of this device.
3. Tighten each two M2.6 screws. The tightening torque should be 0.3N·m or less.
M2.6 screw
Main sensor
End cap
Connector
Connector
Groove
Cable
Sub sensor
(Bottom side)
Connector
Groove
Connector
Cable
Main sensor
(Upper side)
Cable for serial connection
(
SFB-CSL
□) (Optional)
Sub sensor
(Bottom side)
Main sensor
(Upper side)
M2.6 screw
Enclosed with the cable
for sires connection