66
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
<Timing chart (Normal)>
The setting time of the device monitor is 300ms or less. Exceeding 300ms turns the device
into lockout status. It can be set within 100 to 600ms (unit: 10ms) by using the handy controller
(
SFB-HC
) (optional).
<Timing chart (Error 1)>
<Timing chart (Error 2)>
14ms or less
90ms or less
ON
OFF
ON
OFF
300ms or less
Light
blocked
Light
received
External device
monitor input
Light received
status
Control output
(OSSD 1 / 2)
14ms or less
ON
OFF
ON
OFF
300ms
Lockout state
Light
blocked
Light
received
External device
monitor input
Light received
status
Control output
(OSSD 1 / 2)
90ms or less
External device
monitor input
ON
OFF
ON
OFF
300ms
Light
blocked
Light
received
Light received
status
Control output
(OSSD 1 / 2)
Lockout state
300ms or less