![Panasonic SF4B-F31G(V2) Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/panasonic/sf4b-f31g-v2/sf4b-f31g-v2_instruction-manual_3900092052.webp)
52
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
<For NPN output>
Interlock function
Invalid (Auto-reset)
External device monitor function Valid
Auxiliary output
Can be used
The device output is selected depending on the connecting state of the output polarity setting wire
(shield). Incorrect wiring may cause the lockout state.
* Symbols
Switch S1
0 to +1.5V (source current 5mA or less): Emission, Open: Emission halt
Switch S2
The muting input, the override input
0 to +1.5V (source current 5mA or less): Valid, Open: Invalid
K1, K2: External device ( Forced guided relay or magnetic contactor)
Note: The incandescent lamp with 3 to 10W shall be connected to the muting lamp output. If the muting lamp is not
connected, the muting function does not operate.
+ 24V DC
±10%
-
K1
K2
*S1
(Note 1)
*S2
Load
*S2
*S2
K1 K2
Receiver
Emitter
Gray cable
Gray cable
with black line
(Gray) Interference prev
(Gray / Black) Interference prevention -
(Red) Muting lamp output
(Yellow) Override input
(Brown) +V
(Yellow-green) External device monitor input
(Brown) +V
(Shield) Output polarity setting wire
(Blue) 0V
(Sky-blue / White) Muting input A
(Sky-blue / Black) Muting input B
(Gray) Interference prev
(Gray / Black) Interference prevention -
(Pale purple) Interlock setting input
(Pink) Emission halt input / Reset input
(Yellow-green / Black) Auxiliary output
(Shield) Output polarity setting wire
(Orange) Synchroni
(Orange / Black) Synchronization -
(Orange) Synchroni
(Orange / Black) Synchronization -
(Blue) 0V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)