![Panasonic SF4B-F31G(V2) Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/panasonic/sf4b-f31g-v2/sf4b-f31g-v2_instruction-manual_3900092037.webp)
37
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
<For NPN output>
Interlock function
Valid (Manual reset)
External device monitor function Valid
Auxiliary output
Can be used
The device output is selected depending on the connecting state of the output polarity setting wire
(shield) wire. Incorrect wiring may cause the lockout state.
* Symbols
Switch S1
0 to +1.5V (source current 5mA or less): Emission halt, Open: Emission
K1, K2: External device (Forced guided relay or magnetic contactor)
Notes: 1) The circuit diagram shown above is for 12-core cable to be used. For 8-core cable, red, yellow, gray, gray /
black, sky-blue / white, sky-blue / black, there is no lead wire.
2) For resetting, refer to “
3-2 Interlock Function
.”
Receiver 2 sub sensor
Emi
tter 2
su
b se
nso
r
Receiver
1 main sensor
Emitter 1 main sensor
Gray
cable
+ 24V DC
±10%
-
K1
K2
Load
*S1
K1 K2
(Shield) Output polarity setting wire
(Blue) 0V
(Brown) +V
(Pale purple) Interlock setting input
(Gray) Interference prev
(Gray / Black) Interference prevention -
(Red) Muting lamp output
(Yellow) Override input
(Yellow-green) External device monitor input
(Brown) +V
(Shield) Output polarity setting wire
(Sky-blue / White) Muting input A
(Sky-blue / Black) Muting input B
(Gray / Black) Interference prevention -
(Gray) Interference prev
(Pink) Emission halt input / Reset input
(Yellow-green / Black) Auxiliary output
(Blue) 0V
(Orange) Synchroni
(Orange / Black) Synchronization -
(Orange) Synchroni
(Orange / Black) Synchronization -
Gray cable
with black line
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)