Timing chart
Note: This is when the muting lamp diagnosis function is valid. If the muting lamp does not light up even if 1 sec. is
passed, the override function becomes invalid. When the muting lamp diagnosis function is invalid, the muting
function becomes valid 3 sec. after the input conditions of the muting sensor A (C) and B (D) were satisfied.
3-9 Functions Using Handy Controller (SFB-HC) (Optional)
This device enables to set each function using the handy controller (
SFB-HC
) (optional). The
settable functions and the factory setting of each function are as follows.
For details, refer to the instruction manual enclosed with the handy controller.
Among the functions, the contents related to the safety distance such as the size of
the minimum sensing object are varied depending on the setting condition. When
setting each function, re-calculate the safety distance, and make enough space larg-
er than the calculated safety distance. Failure to do so might cause the accident that
the device cannot stop quickly before reaching the dangerous area of the device,
resulting in the death or serious injury.
●
Fixed blanking function
This function enables to protect the control output (OSSD 1 / 2) from turning into OFF even
though the specific beam channel is blocked.
The factory setting is set to be invalid for the fixed blanking function.
●
Floating blanking function
This function enables to protect the control output (OSSD 1 / 2) from turning into OFF even
though the number of the blocked beam channels are lower than that of the setting beam
channels. 1, 2 or 3 beam channels are settable as the blocking beam channels.
The factory setting is set to be invalid for the floating blanking function.
Both fixed blanking function and floating blanking function are settable simultaneously.
●
Emission amount control function
The two modes, normal mode and short mode, can be set / changed by controlling the emis-
sion amount. The factory setting is set to the normal mode for the emission amount control
function.
ON
OFF
ON
OFF
ON
OFF
Open
Short-
circuit
Emission halt
input / Reset
input
Open
Short-
circuit
Override
input
Muting sensor
B / D
Muting sensor
A / C
Override
function
ON
OFF
Absent
Present
Control output
(OSSD 1 / 2)
Sensing object
Within the
protection
area
3 to 4 sec. (Note)
Override input time: Max. 60 sec.
14 ms or less
90 ms or less