60
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
2) When using emission halt function
This device incorporates the emission halt function. Using this function, it is possible to simulate
the light blocked status.
When the emission halt input is kept open (for manual reset: connected to 0V, +V), the emitter stops emit
-
ting light. In this condition, if this device operates properly, the control output (OSSD 1 / 2) of the receiver
turns OFF.
Setting procedure and
check items
Indicators
Control output
Emitter
Receiver
OSSD 1 OSSD 2
1
Before power is ON,
Connect the emis-
sion halt input / reset
input to Vs.
(Note 3)
OFF
2
After power is ON,
Receiver’s control
output (OSSD 1 / 2)
is ON.
(Normal operation)
ON
Notes: 1) Since the color of the operation indicator changes according to the ON / OFF state of the control output
(OSSD 1 / 2), the operation indicator is marked as “OSSD” on the device.
2) The status of the emitter / receiver indicators during operation above shows the case in PNP output
setting mode. In case of NPN output setting mode, the NPN indicator (orange) lights up.
3) Vs is the applying supply voltage.
<Reference>
Beam-axis alignment
indicator
PNP indicator
Emission halt indicator
Operation indicator (Note 1)
Incident light intensity indicator
Fault indicator
Digital error indicator
NPN indicator
Emission intensity control indicator
Beam-axis alignment
indicator (Green)
PNP indicator (Orange) (Note 2)
Emission halt indicator
Operation indicator (Green) (Note 1)
Incident light intensity indicator
Fault indicator
(Green)
Digital error indicator
NPN indicator
Emission intensity control indicator
Interlock indicator
Function setting indicator
Beam-axis alignment
indicator
PNP indicator
OSSD indicator
Incident light intensity indicator
Fault indicator
Digital error indicator
NPN indicator
Interlock indicator
Function setting indicator
Beam-axis alignment
indicator (Green)
PNP indicator (Orange) (Note 2)
OSSD indicator (Green)
Incident light intensity indicator
Fault indicator
Digital error indicator
NPN indicator
(Green)
: Blinks
in orange
: Lights up
in red
: Lights up
in green
: Lights up
in orange
: Turns
OFF