68
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
<Output operation of muting sensors>
Operation at ON state Operation at OFF state
NO (Normally Open) type
ON with light non-received status
(photoelectric sensor, etc.)
ON with object approaching status
(inductive proximity sensor, etc.)
ON with object contacted status
(position switch, etc.)
Output 0V or +V
Open
Be sure to use a muting sensor that satisfies the
<Output operation of muting
sensors>
above. If the other muting sensor not satisfying the specification above,
the muting function might become valid with the timing that the machine designer
cannot expect and could result in death or serious injury.
<Installation condition example of muting sensors>
1) Shorten the distances between muting sensors A to C and between B to D than the whole length of the sensing object.
2) The time of the sensing object to be passed through the muting sensors A to B shall be 0.03 to under 3 sec.
Distance between A and B (m) < S (m/sec.) × 3 (sec.)
S: The moving speed (m/sec.) of the sensing object
3) The time of the sensing object to be passed through the muting sensors C to D shall be under 3 sec.
Distance between C and D (m) < S (m/sec.) × 3 (sec.)
S: The moving speed (m/sec.) of the sensing object.
Light curtain Muting sensor C
Muting sensor D
Muting sensor B
Muting sensor A
Sensing object
S (m/sec)
1
1
2
3
Safety zone
Dangerous zone
Guard
Guard
<For PNP output>
Muting
sensor A
+V
Muting input A
<For NPN output>
0V
Muting input A
0V
+V
Muting input B
0V
Muting input B
0V
Muting
sensor D
Muting
sensor B
Muting
sensor C
Muting
sensor A
Muting
sensor D
Muting
sensor B
Muting
sensor C