![Panasonic SF4B-F31G(V2) Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/panasonic/sf4b-f31g-v2/sf4b-f31g-v2_instruction-manual_3900092013.webp)
13
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
<Display section>
Notes: 1) Since the color of the operation indicator changes according to ON / OFF status of the control output
(OSSD 1 / 2), the operation indicator is marked as “OSSD” on the device.
2) The threshold where the control output (OSSD 1 / 2) changes from OFF to ON is applied as “100%
incident light intensity”.
3) “When light is blocked” refers to the status that there exists any object blocking light in the sensing area.
4) The blanking function is set by using the handy controller (
SFB-HC
) (optional). Please purchase the handy
controller separately.
5) The description given in [ ] is marked on the device.
Description
Function
Beam-axis
alignment indicator
(Red / Green)
[RECEPTION]
A
When device top receives light: lights up in red
When device top end receives light: blinks in red
When control output (OSSD 1 / 2) is ON:
lights up in green
B
When device upper middle receives light: lights up in red
When control output (OSSD 1 / 2) is ON: lights up in green
C
When device lower middle receives light: lights up in red
When control output (OSSD 1 / 2) is ON: lights up in green
D
When device bottom receives light: lights up in red
When device bottom end receives light: blinks in red
When control output (OSSD 1 / 2) is ON:
lights up in green
Operator indicator
(Red / Green) [OSSD]
(Note 1)
Lights up while device operation is as follows
[sequential operation control output (OSSD1 / 2)]
When control output (OSSD 1 / 2) is OFF:
lights up in red
When control output (OSSD 1 / 2) is ON:
lights up in green
Incident light intensity
indicator
(Orange / Green)
[STB.]
When sufficient light is received
(Incident light: 130% or more) (Note 2): lights up in green
When stable light is received
(Incident light: 115 to 130%) (Note 2): OFF
When unstable light is received
(Incident light : 100 to 115%) (Note 2): lights up in orange
When light is blocked: OFF (Note 3)
Fault indicator (Yellow)
[FAULT]
When fault occurs in the device:
lights up or blinks
Digital error indicator
(Red)
When device is lockout, error contents are indicated.
When the sensors are connected in paral-
lel, the bottom of the digital error indicator
on the slave side sensors lights up in red.
PNP indicator (Orange)
[PNP]
When PNP output is set: lights up
NPN indicator (Orange)
[NPN]
When NPN output is set: lights up
Emission intensity
control indicator
(Orange) [CTRL]
When light is emitted under short mode:
lights up
When light is emitted under normal mode: OFF
Emission halt indicator
(Orange) [HALT]
When light emission is halt: lights up
When light is emitted: OFF
Description
Function
Beam-axis
alignment indicator
(Red / Green)
[RECEPTION]
A
When device top receives light: lights up in red
When device top end receives light: blinks in red
When control output (OSSD 1 / 2) is ON:
lights up in green
B
When device upper middle receives light: lights up in red
When control output (OSSD 1 / 2) is ON: light up in green
C
When device lower middle receives light: lights up in red
When control output (OSSD 1 / 2) is ON: lights up in green
D
When device bottom receives light: lights up in red
When device bottom end receives light: blinks in red
When control output (OSSD 1 / 2) is ON:
lights up in green
OSSD indicator
(Red / Green) [OSSD]
When control output (OSSD 1 / 2) is OFF:
lights up in red
When control output (OSSD 1 / 2) is ON:
lights up in green
Incident light intensity
indicator
(Orange / Green)
[STB.]
When sufficient light is received
(Incident light: 130% or more) (Note 2): lights up in green
When stable light is received
(Incident light: 115 to 130%) (Note 2): OFF
When unstable light is received
(Incident light : 100 to 115%) (Note 2): lights up in orange
When light is blocked: OFF (Note 3)
Fault indicator (Yellow)
[FAULT]
When fault occurs in the device:
light up or blinks
Digital error indicator
(Red)
When device is lockout, error contents are indicated.
When the sensors are connected in paral-
lel, the bottom of the digital error indicator
on the slave side sensors lights up in red.
PNP indicator (Orange)
[PNP]
When PNP output is set: light up
NPN indicator (Orange)
[NPN]
When NPN output is set: lights up
Function setting indicator
(orange) [FUNCTION]
When blanking function is used:
lights up (Note 4)
When connecting the handy controller: brinks
Interlock indicator
(Yellow) [INTERLOCK]
When device is interlocked: lights up
Other cases: OFF
Emitter
Receiver
Incident light intensity indicator [STB.]
Digital error indicator
Beam-axis alignment indicator
[RECEPTION]
Operation indicator [OSSD]
PNP indicator [PNP]
NPN indicator[NPN]
Emission intensity control indicator
[CTRL]
Emission halt indicator [HALT]
Fault indicator [FAULT]
Incident light intensity indicator [STB.]
Digital error indicator
Beam-axis alignment indicator
[RECEPTION]
OSSD indicator [OSSD]
PNP indicator [PNP]
NPN indicator [NPN]
Function setting indicator
[FUNCTION]
Interlock indicator [INTERLOCK]
Fault indicator [FAULT]
Beam-axis
alignment
indicator
[RECEPTION]
Top end
Bottom end