Section 700 - Operation
Chapter 4. User Maintenance
S-ICX-50-700
S-ICX (International) issued October 2000
83
Table 10.
Day of the Week - addresses
Hardware Requirements
•
N/A
Considerations
•
N/A
Set Exception Day Mode
Description
(For a description of Automatic Day/Night System Mode, see “Automatic Day/Night Mode” on page
36.)
You can specify exception days which allow for a range of days for the System to operate in the Night
mode. This is intended for extended holidays for business shut down periods that last for multiple
days. You can specify up to 6 exception day periods.
Operation
To set the Exception Day Modes:
ADDRESSES
FOR THESE
DAYS OF THE
WEEK:
--
DAY OCCURRENCE
--
(e.g., 1st Sunday=address 300; 2nd Sunday=address 307)
1st
2nd
3rd
4th
5th
Sunday
300
307
314
321
328
Monday
301
308
315
322
329
Tuesday
302
309
316
323
330
Wednesday
303
310
317
324
331
Thursday
304
311
318
325
332
Friday
305
312
319
326
333
Saturday
306
313
320
327
334
Action
Result
1. If not already in User Maintenance mode, enter User Main-
tenance mode. (See “To enter User Maintenance mode:” on
page 75.)
81-
User MAINT
displays
2. At the
81
level, enter
07
.
3. Press the
HOLD
key.
8107-
System Mode
displays
4. Enter
2
.
5. Press the
HOLD
key.
2-
Mode Except Day
displays