INF - 18
6. 3. System log data acquisition method
6. 3. 1. Equipment to be used
1. Computer : Use it for collection of log data.
2. Communication cable : D-sub 9pin (male/female RS-232C straight)
3. Service Software :
[
DataLogBackup.exe
]
Service software is downloaded from the projector service homepage.
6. 3. 2. Preparation
[Caution]
・
Set the "SERIAL" in "RS-232C INPUT SELECT"
of "PROJECTOR SETUP" menu.
6. 3. 3. Acquisition of log data
1. Switch the projector to "Normal-Standby" mode (POWER indicator is Lighting in red).
2. Start up service software
[
DataLogBackup.exe
]
with a computer.
3. Select "Option "
→
" Setting" and set Serial Port of the computer, Baud Rate and Parity.
4. Select a model number and ID.
1. Confirm and make a note of "Projector ID",
"Transmission speed" and ""Parity setting".
2. Correct the serial terminals on the projector and
the PC by using a communication cable.
Computer
RS-232C straight
Projector
Содержание PT-RZ470 Series
Страница 6: ...6 2 Specifications...
Страница 7: ...7...
Страница 9: ...INF 2 1 The name of each part 1 1 Projector body 1 2 Control panel...
Страница 10: ...INF 3 1 3 Connecting terminals 1 4 Remote control...
Страница 11: ...INF 4 2 OSD Menu Navigation...
Страница 12: ...INF 5...
Страница 13: ...INF 6...
Страница 26: ...INF 19 5 Select Log SYSTEM and click Get button 6 Log is displayed...
Страница 84: ......