Chapter 5
Maintenance — [SELF TEST] indications
162 - ENGLISH
[SELF TEST] indications
Details and measures for the alphanumeric symbols indicated in [SELF TEST] from the [PROJECTOR SETUP] menu
→
[STATUS] are as
follows.
Self-test indication
Details
Measure
U11
Intake air temperature warning
f
The operating environment temperature is too
high. Install the projector in a location with the
operating environment temperature between 0 °C
(32 °F) and 45 °C (113 °F).
U12
Optical module temperature warning
U13
Exhaust air temperature warning
U14
Low temperature warning
f
The operating environment temperature is too low.
Install the projector in a location with the operating
environment temperature between 0 °C (32 °F)
and 45 °C (113 °F).
U16
Light source 1 temperature warning
f
The operating environment temperature is too
high. Install the projector in a location with the
operating environment temperature between 0 °C
(32 °F) and 45 °C (113 °F).
U17
Light source 2 temperature warning
U21
Intake air temperature error
U22
Optical module temperature error
U23
Exhaust air temperature error
U24
Low temperature error
f
The operating environment temperature is too low.
Install the projector in a location with the operating
environment temperature between 0 °C (32 °F)
and 45 °C (113 °F).
U25
Light source 1 temperature error
f
The operating environment temperature is too
high. Install the projector in a location with the
operating environment temperature between 0 °C
(32 °F) and 45 °C (113 °F).
U26
Light source 2 temperature error
U81
Low AC voltage warning (below 90 V)
f
The input power supply voltage is low. Use electric
wiring that can sufficiently withstand the power
consumption of the projector.
H01
Battery replacement for the built-in clock
f
Battery replacement is required. Consult your
dealer.
H11
Intake air temperature sensor not present
f
If the display does not clear after switching the
main power off and on, consult your dealer.
H12
Optical module temperature sensor not present
H13
Exhaust air temperature sensor not present
H14
Light source 1 temperature sensor not present
H15
Light source 2 temperature sensor not present
F00
Liquid cooling pump 1 warning
f
If the display does not clear after switching the
main power off and on, consult your dealer.
F01
Liquid cooling pump 2 warning
F15
Brightness sensor error
F50
Intake fan 3 warning
F51
Phosphor wheel 1 fan warning
F52
Phosphor wheel 2 fan warning
F53
Power intake fan warning
F54
Drive fan warning
F55
Power exhaust fan warning
F56
DMD fan warning
F57
Exhaust fan 1 warning
F58
Exhaust fan 2 warning
F59
Intake fan 2 warning
F61
LD driver 1 communication error
F62
LD driver 2 communication error
F65
LD sub-microcomputer error
F70
Intake fan 1 warning
F85
Color wheel error (FM)
f
If the display does not clear after switching the
main power off and on, consult your dealer.
F86
Color wheel error (FPGA)
F90
FPGA configuration error
F91
FPGA1 configuration error
F92
FPGA2 configuration error
F96
Lens mounter error
F97
Geometric adjustment board communication error
FA8
Light source 1 error
f
If the display does not clear after switching the
main power off and on, consult your dealer.