Chapter 4
Settings — [PROJECTOR SETUP] menu
124 - ENGLISH
4)
When the confirmation screen is displayed, press
qw
to select [OK], and press the <ENTER> button.
f
[PROGRESS] is displayed while saving data.
Note
f
Data set from the computer application is not included in [ALL USER DATA].
[LOAD ALL USER DATA]
Load the various setting values saved as a backup in the built-in memory of the projector.
1) Press
as
to select [LOAD ALL USER DATA].
2) Press the <ENTER> button.
f
The
[SECURITY PASSWORD]
screen is displayed.
3)
Enter a security password and press the <ENTER> button.
4)
When the confirmation screen is displayed, press
qw
to select [OK], and press the <ENTER> button.
Note
f
The projector enters the standby mode to reflect the setting values when [LOAD ALL USER DATA] is executed.
f
Data registered from a computer is not included in [ALL USER DATA].
[INITIALIZE]
Return various setting values to their factory default settings.
1) Press
as
to select [INITIALIZE].
2) Press the <ENTER> button.
f
The
[SECURITY PASSWORD]
screen is displayed.
3)
Enter a security password and press the <ENTER> button.
f
The
[INITIALIZE]
screen is displayed.
4) Press
as
to select an item to initialize.
[ALL USER DATA]
Returns all setting values including [REGISTERED SIGNAL], [NETWORK SETUP], [E-mail set up],
and [USER LOGO] to the factory default settings.
The projector enters the standby mode to reflect the setting values.
[REGISTERED SIGNAL]
Deletes all the setting values saved for each input signal.
To delete only a part of a registered signal, perform the procedure described in “Deleting the
registered signal” (
x
page 128).
[NETWORK/E-MAIL]
Returns [NETWORK SETUP] and [E-mail set up] to factory default settings.
[LOGO IMAGE]
Deletes the image registered in [USER LOGO].
5) Press the <ENTER> button.
6)
When the confirmation screen is displayed, press
qw
to select [OK], and press the <ENTER> button.
Note
f
Even when [ALL USER DATA] is executed, [UNIFORMITY], [OPERATING MODE], [MAX LIGHT OUTPUT LEVEL], and [STANDBY MODE]
settings are not initialized.
[SERVICE PASSWORD]
This function is used by a service person.