131
Screen Description
No.
Displays the port-number.
Admin
Displays if the power supply can be operated.
The factory default settings is “Up”.
Up
Indicates that power supply is possible.
Down
Indicates that power supply is impossible.
Status
Displays the status of power supply.
Pwr
Indicates that PoE power-supply is operated.
NotPwr
Indicates that PoE power-supply is not operated.
Over
Indicates that operating the power supply stops because of the
requirement for the power supply exceeding the upper-limit of the
power supply (amount).
Layer
Displays the classification-method compatible with the terminal equipment.
1
Indicates that the power supply is operated in accordance with the
Physical Layer Classification.
2
Indicates that the power supply is operated in accordance with the
Data Link Lalyer Classification.
Class
Displays Class detected by the classification.
Prio.
Displays the priority of the power supply.
Crit.
Indicates that this task is to be performed as the highest priority.
High
Indicates that this task is performed as the lower priority than Crit.
Low
Indicates that low is not a priority.
Limit
Displays the upper-limit of the power supply (200mW: unit). The factory default
settings is “Auto”.
Pow.
Displays the power supply (100mw: unit).
Vol.
Displays the voltage value (1V: unit).
Cur.
Displays the current value (1mA: unit).