The following describes how to use several commands on this screen.
Coldstart
Trap Control
Displays the configuration of enabling and disabling outgoing traps when the
device executes Coldstart.
Enabled
Enables outgoing traps.
Disabled
Disables outgoing traps (factory default settings).
Warmstart
Trap Control
Displays the configuration of enabling and disabling outgoing traps when the
device executes Warmstart.
Enabled
Enables outgoing traps.
Disabled
Disables outgoing traps (factory default settings).
A
Configures to enable or disable outgoing traps when the SNMP authentication becomes failed.
Press A (command), and then the appearance of the command prompt becomes “Enable or
Disable SNMP Authentication trap(E/D)>”. After that, press E to enable outgoing traps and
D to disable it.
P
Adds the target port of outgoing traps when changing the link-condition is necessary.
Press P, and then the appearance of the command prompt becomes “Enter port-numbers
(up to xx ports)>”. After that, enter the target port-number for outgoing traps. Press 0 when
changing all the ports, simultaneously.
O
Deletes the target port of outgoing traps when changing the link-condition is necessary.
Press O, and then the appearance of the command prompt becomes “Enter port-numbers
(up to xx ports)>”. After that, enter the port-number to be deleted from the target of
outgoing traps. (Press 0 when changing all the ports, simultaneously.)
U
Configures to enable or disable outgoing traps when the port becomes link-up.
Press U, and then the appearance of the command prompt becomes “Enable or Disable
SNMP Authentication trap(E/D)>”. After that, press E to enable outgoing traps and D to dis
-
able it.
D
Configures to enable or disable outgoing traps when the port becomes link-down.
Press D, and then the appearance of the command prompt becomes “Enable or Disable
SNMP Authentication trap(E/D)>”. After that, press E to enable outgoing traps and D to dis
-
able that.
E
Configures to enable or disable outgoing traps during the PoE power-supply.
Press E, and then the appearance of the command prompt becomes “Enable or Disable
SNMP Authentication trap(E/D)>”. After that, press E to enable outgoing traps and D to dis
-
able that.
C
Configures to enable or disable outgoing traps when the device executes Coldstart.
Press C, and then the appearance of the command prompt becomes “Enable or Disable
SNMP Authentication trap(E/D)>”. After that, press E to enable outgoing traps and D to
disable that.
W Configures to enable or disable outgoing traps when the device executes coldstart.
Press W, and then the appearance of the command prompt becomes “Enable or Disable
SNMP Authentication trap(E/D)>”. After that, press E to enable outgoing traps and D to dis
-
able that.
Q
Returns to the top menu.