37
Screen Description
Console UI Idle
Time Out
Displays time as the minute unit until a session exits if nothing is entered and a
console is connected. The factory default settings is three (3) minutes.
Telnet UI Idle
Time Out
If remote connection is operated with Telnet, the screen will display the time
needed as a minute-unit until a session is disconnected if nothing is entered.
The factory default settings is three (3) minutes.
Telnet Server
Displays if the access with Telnet works. The factory default settings is set to
Disabled.
Enabled:
Accessible
Disabled:
Inaccessible
SNMP Agent
Displays if the access with SNMP works. The factory default settings is set to
Disabled.
Enabled:
Accessible
Disabled:
Inaccessible
Web Server
Status
If a function of WEB authentication is enabled on CLI, it becomes changed to
Enable automatically. If Web Server Status becomes disabled, be careful with
that as the function of WEB authentication is not used. Use CLI when configuring
the function of WEB authentication. The factory default settings is set to
Disabled.
Enabled:
Accessible
Disabled:
Inaccessible
IP Setup
Interface
Displays if the access with the software of the IP address configuration, which is
included in a network camera produced by Panasonic and “ZEQUO assist Plus”
as a support tool of our switching hub, is possible. The factory default setting is
“Enabled”. Note: See section 3.5.3 for the caveats.
Enabled:
Accessible
Disabled:
Inaccessible
Local User Name Displays the user-name, which is configured currently
to log in. Manager is set to
the factory default settings. Use CLI when changing a user name.
Syslog
Transmission
Displays if the system log is transmitted to Syslog servers.
The factory default settings is set to Disabled.
Enabled:
System log is transmitted to the Syslog server.
Disabled:
System log is not transmitted to the Syslog server.
Login Method 1
Displays a user-name, which is currently configured to log in.
The factory default settings is local.
Local
Log in to your device using a user name and a password config
-
ured.
RADIUS
Use an authentication operated by the RADIUS server to log in.
Login Method 2
Displays how to check a user-name and a password that are used to log in. The
factory default settings is None.
Local
Log in to your device using a user name and a password.
None
The login method 2 is not used.