No. SX-DSV02829 -
122-
4) Relevant parameters
The operation of
model type damping filter
is configured using the following parameters.
Class No.
Attri
bute
*1)
Title
Range
Unit
Function
6
47
R
Function expansion
setup 2
0-127
-
Set various functions with bits.
bit0 2 degrees of freedom control mode
0: Disabled 1: Enabled
bit5 Model type damping filter
0: Disabled 1: Enabled
*To enable the model type damping filter, bit0 and bit5 need to b
e set to “1”.
6
61
B
1st resonance
frequency
0-3000
0.1Hz
Sets the 1st resonance frequency of the load in mode of model
type damping filter enabled.The unit is [0.1Hz].
Setting possible within the scope of the 10.0 [Hz]
≦
1st Anti-resonance frequency<1st Resonance frequency
≦
300.0 [Hz].
If the setting value is not the above magnitude relationship,vibration
suppression filter and filter resonance characteristic is invalid.
6
62
B
1st resonance
damping ratio
0-1000
-
Sets the 1st resonance damping ratio of the load in mode of model type
damping filter enabled.
Damping ratio is set by the setting value × 0.001.
When the set value of 1000, damping 1 (no peak).
Decreasing the setting value, the damping ratio is reduced. (Resonance
peak is large)
6
63
B
1st anti-resonance
frequency
0
~
3000
0.1Hz
Sets the 1st anti-resonance frequency of the load in mode of model type
damping filter enabled.The unit is [0.1Hz].
Setting possible within the scope of the 10.0 [Hz]
≦
1st Anti-resonance frequency<1st Resonance frequency
≦
300.0 [Hz].
If the setting value is not the above magnitude relationship,vibration
suppression filter and filter resonance characteristic is invalid.
6
64
B
1st anti-resonance
damping ratio
0-1000
-
Sets the 1st anti-resonance damping ratio of the load in mode of model
type damping filter enabled.
Damping ratio is set by the setting value x 0.001.
When the set value of 1000, damping 1 (no peak).
Decreasing the setting value, the damping ratio is reduced. (Resonance peak is
large)
6
65
B
1st response
frequency
0-3000
0.1Hz
Sets the 1st response damping ratio of the load in mode of model type
damping filter enabled.The unit is [0.1Hz].
Setting possible within the scope of the 10.0 [Hz]
≦
1st anti-resonance frequency
≦
1st response frequency
≦
1st anti-resonance frequency x 4
≦
300.0 [Hz].
If the setting value is not the above magnitude relationship,vibration
suppression filter and filter resonance characteristic is invalid.
6
66
B
2nd resonance
frequency
0-3000
0.1Hz
Sets the 2nd resonance frequency of the load in mode of model type
damping filter enabled. The unit is [0.1Hz].
Setting possible within the scope of the 10.0 [Hz]
≦
2nd Anti-resonance
frequency<2nd Resonance frequency
≦
300.0 [Hz].
If the setting value is not the above magnitude relationship, vibration
suppression filter and filter resonance characteristic is invalid.
6
67
B
2nd resonance
damping ratio
0-1000
-
Sets the 2nd resonance damping ratio of the load in mode of model type
damping filter enabled.
Damping ratio is set by the setting value x 0.001.
When the set value of 1000, damping 1 (no peak).
Decreasing the setting value, the damping ratio is reduced. (Resonance
peak is large)
6
68
B
2nd anti-resonance
frequency
0-3000
0.1Hz
Sets the 2nd anti-resonance frequency of the load in mode of model type
damping filter enabled.The unit is [0.1Hz].
Setting possible within the scope of the 10.0 [Hz]
≦
2nd Anti-resonance
frequency<2nd Resonance frequency
≦
300.0 [Hz].
If the setting value is not the above magnitude relationship, vibration
suppression filter and filter resonance characteristic is invalid.
(To be continued)
R1.00
Motor Business Unit, Panasonic Corporation